Introduction
2-1
2 Introduction
Overview
The Century Series Advanced Integrated Circuit Encapsulation (AICE) systems are designed to solve the
diverse needs of the emerging flip chip underfill and IC encapsulation market. The Century Series C-721
Dispensing System provides a modular approach to hardware, software, and factory integration.
Advanced platform architecture provides precision control for reliable fluid delivery, with closed-loop
thermal management, multi-zone substrate heating, and flexible material handling capabilities.
The Century C-721 system features a SMEMA-compatible material handling system that can be
configured for a variety of substrate types and sizes. Process carriers, lead frames, and multiple substrate
carriers are all supported. Optional contact or impingement part heaters ensure reliable and flexible
substrate heating.
An integrated vision system for flip chip corner detection automatically corrects any workpiece
misalignment. Asymtek’s exclusive Fluidmove for Windows NT (FmNT) software controls all machine
parameters and events within a familiar Windows environment. Key safety features meet Common
European (CE) standards.
Basic System Description
All Century Series dispensing systems begin with a standard platform. Modular components are added,
allowing the system to be configured for common AICE applications. Your system was configured for
your application at the Asymtek factory prior to shipping. Detailed descriptions of all features are found
later in this section.
Basic Platform
•
Computer system
•
Vision system
•
Light beacon
•
Vision system lighting
•
Motorized conveyor width adjust
•
Fluid pump quick refill
•
Vacuum-operated purge station
•
O-ring conveyor
•
Fluidmove for Windows NT software
•
Two-station lift tables
•
Needle sensor
•
Temperature controller
Optional Modular Components
•
Part heaters (contact or impingement)
•
Dual-action dispensing head
•
Fluid dispensing pumps
•
Low air pressure sensor
•
Needle heater
•
Low fluid sensor
•
Height sensor
•
Hour meter
System Features
The figures in this section show views and features of the dispensing system. Callouts locate major
components, options, and switches seen in each illustration. Paragraphs following the views briefly
describe each feature.
Содержание Century C-721 Series
Страница 2: ...Revision History Revision Date Description Pages Affected A 5 01 Initial Release All ...
Страница 8: ......
Страница 12: ......
Страница 36: ......
Страница 76: ......
Страница 81: ...Maintenance 7 5 Item Description 1 Purge Boot 2 Purge Station Lid Figure 7 2 Replacing the Purge Boot 1 2 ...
Страница 108: ......
Страница 112: ...11 4 Needle Sensor Item Description 1 Tactile sensor hat 2 Tactile sensor Figure 11 2 Tactile Sensor Exposed 1 2 ...
Страница 114: ......
Страница 117: ...Needle Heater 12 3 Figure 12 2 HT 06 Figure 12 3 HT 10N ...
Страница 119: ...Needle Heater 12 5 Item Description 1 Luer Lock Fitting Figure 12 4 HT 06 on a DV 6000 Pump with Luer Lock Fitting 1 ...
Страница 122: ......
Страница 138: ......