6-2
Troubleshooting
System Troubleshooting
Use Table 6-2 to determine the possible cause of minor hardware problems, and follow the recommended
recovery procedures to resolve the problem.
For problems related to major components, such as the
conveyor, or heater problems, please refer to the section of this manual specific to that component for
troubleshooting help.
For problems not addressed in Table 6-2, refer to the “Troubleshooting” section of the C-721
Installation
and Service
Manual
or contact Asymtek Technical Support.
Table 6-2 System Troubleshooting
Symptom
Possible Cause
Recovery
Main Power Cable
disconnected.
Check that the Main Power Cable is
connected to an AC source.
Main Power Circuit Breaker
turned OFF.
Turn ON the Main Power Circuit Breaker at
the rear of the system.
EMO is depressed.
1. Turn EMO clockwise until it releases.
2. Close
doors.
3. Press Start button (
I
) on Control Panel.
4. Press
Find Home
.
Interlock activated (doors
opened, low air pressure
sensor tripped).
1. Close the front doors.
2. Press
Reset
. Wait 3 seconds.
3. Press
Find Home
.
Blown fuse in dispenser.
Contact Technical Support.
No power to major
system components.
The Start (
I
) button has not
been pressed.
Press the Start (
I
) button on the Dispenser
Control Panel.
Nozzle/needle is damaged.
Replace needle and perform
Valve
Offsets
or
Calculate Master Offsets
(see
B below).
Nozzle/needle has been
changed.
1. From the FmNT Main Window, click on
Configuration
.
2. Select
Needle Setup
.
3. Select
Valve Of
fsets (for DJ-2100) or
Calculate Master Offsets
(for
DV-7000 or DV-6000).
Camera position has
changed.
Perform
Valve Offsets
or
Calculate
Master Offsets
(see B above). If problem
persists, contact Technical Support.
Dispenses in the wrong
X and Y location.
XY location in FmNT program
is incorrect.
Have supervisor edit program.
Содержание Century C-721 Series
Страница 2: ...Revision History Revision Date Description Pages Affected A 5 01 Initial Release All ...
Страница 8: ......
Страница 12: ......
Страница 36: ......
Страница 76: ......
Страница 81: ...Maintenance 7 5 Item Description 1 Purge Boot 2 Purge Station Lid Figure 7 2 Replacing the Purge Boot 1 2 ...
Страница 108: ......
Страница 112: ...11 4 Needle Sensor Item Description 1 Tactile sensor hat 2 Tactile sensor Figure 11 2 Tactile Sensor Exposed 1 2 ...
Страница 114: ......
Страница 117: ...Needle Heater 12 3 Figure 12 2 HT 06 Figure 12 3 HT 10N ...
Страница 119: ...Needle Heater 12 5 Item Description 1 Luer Lock Fitting Figure 12 4 HT 06 on a DV 6000 Pump with Luer Lock Fitting 1 ...
Страница 122: ......
Страница 138: ......