background image

Version 01-2013A

Содержание QAM BOX

Страница 1: ...Version 01 2013A...

Страница 2: ...ps using the web browser interface page 08 Configuring input properties page 11 Configuring output properties page 12 NIT Processing page 17 Sorting programmes the LCN table page 18 Network settings p...

Страница 3: ...Horizontal Low 3 Vertical High 4 Horizontal High SAT output or loop through sockets 5 Horizontal High 6 Vertical High 7 Horizontal Low 8 Vertical Low 9 Test point 20 dB 10 Output socket for RF signal...

Страница 4: ...uations as far as possible you must adhere to the following To operate the device protection class I it is essential that it is connected to a mains socket with protective earth The mains plug functio...

Страница 5: ...d in a cabinet ensure adequate air convection is possible to avoid exceeding the maximum permitted ambient temperature The permitted ambient temperatures specified in the technical data must be compli...

Страница 6: ...nfigure the device using the web browser interface connect your network or laptop PC to the RJ 45 socket on the QAM BOX see position 14 in the figure at the left 2 Connect the SAT input sockets see po...

Страница 7: ...inputs on the device 3 Connect the bus connection sockets on the QAM BOX modules to each other 4 Connect the RF output socket see position 10 left on the QAM BOX with set top boxes or a TV sets with...

Страница 8: ...be able to see the input screen for the user authentication see figure 4 below When the device is still in its delivery state you must use the following log in data User name user or admin input with...

Страница 9: ...New Password 05 A password must have at least 5 characters To delete a user account tick the corresponding checkbox Delete in the right hand column of the ta ble You can also make the following settin...

Страница 10: ...nder currently selected C N signal to noise ratio C N Reserve reserve until the tuner switches off Power input power BER bit error rate of the input signal Frequency output frequency set for the QAM c...

Страница 11: ...selected the preferred value click on Submit to save the selection Click on the Reset form button to delete the values which were entered beforehand Entering input assignment You can make the setting...

Страница 12: ...set form button to delete the values which were entered beforehand 05 If you selected Quatro switch as a value in the Configuration of the external unit table then only the drop down list for the sate...

Страница 13: ...rror message is confirmed by clicking the OK button the maximum value will be entered This will only be saved once the Submit button under the table has been clicked RF ENABLE Activate this output by...

Страница 14: ...uired value in kBaud in the input field Apply settings to all channels tick the checkbox if you wish to apply the values entered to all the QAM channels Save the changes by clicking on the Submit butt...

Страница 15: ...utton to delete the values which were entered beforehand You can have a detailed view of the settings for an FM channel displayed by clicking on the channel number in the first column of the FM Channe...

Страница 16: ...ent field then this setting will be transmitted until a PI is provided by the station Programme Type PTY set the transmission of the channel type ID here Activate dynamic generation of the channel typ...

Страница 17: ...current time to be displayed in the reception device Activate the radio button off if the current time should not be displayed in the reception device Once you have selected the preferred option click...

Страница 18: ...ll no longer be displayed but rather the IP address for the re spective module If external transport streams are added to the NIT then a checkbox will be displayed in the Remove external TS column for...

Страница 19: ...Figure 19 Network settings You can check or set the following properties in detail IP Interface settings MAC shows the MAC address Mode displays the available bandwidth 100 Mbit s Address shows the IP...

Страница 20: ...05 Once you have clicked the Load factory settings button all settings made up to this point will be deleted except for the network and user settings Click on Restart QAM BOX to perform a reboot Chec...

Страница 21: ...h the event occurred If you no longer wish to have the existing entries displayed following a refresh then tick the checkbox Clear log on refresh If the checkbox has been ticked and a refresh is carri...

Страница 22: ...appear Data transmission by the SAT input channels Figure 22 SAT input channel statistics For each tuner the following values for the data transmission properties are displayed for analysis pur poses...

Страница 23: ...network settings SNTP server When expert mode is activated you will see additional properties in the Time settings table under the menu item Network settings You can enter the IP address of a time se...

Страница 24: ...orresponding checkbox you can define which events will be logged in the service log SNMP trap receiver define the trap receiver SNMP trap community define the trap community here SNMP trap filter defi...

Страница 25: ...o the factory default settings click the Load factory default settings button 05 Once you have clicked the Load factory default settings button all settings made up to this point will be deleted excep...

Страница 26: ...to start the upload process The following files are available for download System settings XML format Channel list XML format Local NIT XML format Local LCN XML format SAT database XML format Simply...

Страница 27: ...select the action to be performed from the drop down list The action can only be performed when the specified server path does actually exist Furthermore any firewall which has been set up must be con...

Страница 28: ...ng the programme Tftpd32 is described in the following Figure 31 Example view of the QAM BOX update folder with update files and tftpd32 programme You can file and launch the tftpd32 programme directl...

Страница 29: ...update proceed as follows Open the Update area in the web browser interface by clicking on the corresponding entry in the menu at the left Enter the IP address of the local PC in the line T FTP Server...

Страница 30: ...be resolved please contact the ASTRO customer service Maintenance and repair The device must not be opened other than for repair purposes Repairs may only be carried out at the factory or at workshops...

Страница 31: ...ions free selectable Input symbol rate MS s DVB S 1 45 DVB S2 2 47 QPSK 2 31 5 8PSK Input level dB V 60 90 QAM modulator Modulation 16 32 64 128 256 QAM Frequency range MHz 47 862 digitally modulated...

Страница 32: ...in part or in full without the prior permission of the ASTRO company This manual created by ASTRO Strobel Kommunikationssysteme GmbH Olefant 1 3 D 51427 Bergisch Gladbach Bensberg Tel 02204 405 0 Fax...

Отзывы: