Table 3. RTD Sensor Resistance
Temperature
Ohms
0 °C (32 °F)
100
38 °C (100 °F)
115
66 °C (150 °F)
126
93 °C (200 °F)
136
121°C (250 °F)
147
149 °C (300 °F)
158
177 °C (350 °F)
168
204 °C (400 °F)
178
Same RTD sensor is used in tank, hose and applicator.
Table 5. Valve Coil Resistance
E100XT Style Coil
E900 Style Coil
Voltage Ohms
Voltage Ohms
100
39–42
100
64–75
115
45–48
115
77–89
200
156–157
200
239–281
230
172–201
230
285–335
40
LS10 and LS20 19600-121
Copyright 2010 Astro Packaging