background image

EPA  Wood-Burning Fireplace
P/N  900120-00  REV. E  06/2016 

MONTE

MODEL

MONTECITO™

INSTALLATION AND 
OPERATION INSTRUCTIONS

SAVE THESE INSTRUCTIONS

FOR FUTURE REFERENCE 

Listed to standards:
ULC-S610 and UL-127

Report #   14-199
EPA Cert. No. 537

     

WARNING

 

Hot! Do not touch!  The glass and 
surfaces of this appliance will be hot 
during operation and will retain heat 
for a while after shutting off the appli-
ance.  Severe burns may result. 

• 

 

Carefully supervise children in the 
same room as appliance.

•  If small children are present in the home, it is 

recommended that this appliance be fi tted with 
an adjustable safety gate or barrier screen.

       WARNING

 

The fi replace cannot be operated without a door 
or fi rescreen.  Consult your dealer to select the 
correct replacement door or fi rescreen.

 

The fi replace is equipped with a blower, electri-
cal connection must be made prior to fi replace 
installation

 

Important! To assure proper alignment of glass 
doors: Install this fi replace in a square and 
plumb condition, using shims as necessary at 
sides and/or bottom.

 

Install the fi replace only as described in these 
instructions.

This installation manual will enable you to obtain a safe, effi cient 
and dependable installation of your fi replace system. Please read 
and understand these instructions before beginning your installation.

Do not alter or modify the fi replace or its components under any cir-
cumstances.  Any modifi cation or alteration of the fi replace system, 
including but not limited to the fi replace, chimney components and 
accessories, may void the warranty, listings and approvals of this system 
and could result in an unsafe and potentially dangerous installation.

IHP wood-burning fi replaces are designed for use as a supplemental 
heater.   They are not intended for continuous use as a primary heat 
source.

Fireplace, also for use in mobile or 

manufactured homes with solid fuel only.

A French manual is available upon request. Order P/N 900121-00.

Ce manuel d’installation est disponible en francais, simplement en faire 
la demande. Numéro de la pièce 900121-00.

P900120-00

C

US

Содержание montecito

Страница 1: ...doors Install this fireplace in a square and plumb condition using shims as necessary at sides and or bottom Install the fireplace only as described in these instructions This installation manual will...

Страница 2: ...ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the seller warrants smoke free operat...

Страница 3: ...ing Chimney lengths Elbows where necessary Associated components as per these installation instructions 6 diameterchimney ModelDuraTech DTC manufactured by DuraVent only including Chimney lengths Elbo...

Страница 4: ...g 10 to 20 minutes after reloading depending on the heat and on the moisture content of the wood Onceyouhavereachedthedesiredtemperature the air boost can be closed and the primary air set to a medium...

Страница 5: ...r Recommended Carbon Monoxide Poisoning Early signs of carbonmonoxidepoisoningaresimilartotheflu withheadaches dizzinessand ornausea Ifyou have these signs obtain fresh air immediately Somepeoplearemo...

Страница 6: ...NOTE The use of a firewood moisture meter is rec ommended to ensure the firewood contains less than 20 moisture Seasoning Guide Softwoods 6 months to 18 months Hardwoods 12 months to 24 months Logsth...

Страница 7: ...supplied will be necessary for this adjustment Checking Door Seal A one inch strip of paper may be used to perform a test of the integrity of the door seal Close the door on the paper in at least eigh...

Страница 8: ...ust cover the entire width of the fireplace The combustible floor in front of the fireplace must be covered with a non combustible ma terial tile marble stone etc See Figure 7 COLD CLIMATE INSTALLATIO...

Страница 9: ...instructions Product designs materials dimensions specifications colors and prices are subject to change or discontinuance without notice Allframingdimensionscalculatedfor 1 2 dry wall at the firepla...

Страница 10: ...hermal Barrier 8 Level 7 2 1 m Min 6 8 2 m Min 8 2 4 m Level 42 1067mm 2 x 3 Min 51mm x 76mm Rock Board or Other Noncombustible Facing Drywall NOTE It is recommended that the chase walls and floor be...

Страница 11: ...REPLACE BLOWER The fireplace comes equipped with a heat acti vated blower It is located in the bottom of the fireplace towards the back It uses 120V and must be connected to the main electrical circui...

Страница 12: ...a 5 diameter flexible pipe for the complete run up to thirty 30 feet and a 6 diameter pipe for a run of up to forty 40 feet The duct system must be installed respecting the following 1 Removetheplates...

Страница 13: ...Outside Intake Screw Opening Facing Down Wall Aluminum Tape Plastic Cover Insulation Flexible Pipe Aluminum Tape NOTE 2 clearancetocombustiblesaroundchimneycomponentsrequired NOTE Blown or fill type...

Страница 14: ...hing under the upper shingles and on top of the lower shingles Nail the flashing to the roof using roofing nails 6 Place the spacers and the storm collar over the flashing and tighten it with the bolt...

Страница 15: ...e a plumb bob to line up the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below...

Страница 16: ...6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm 95 3 4 2432 mm...

Страница 17: ...led Only one is required NOTE 45 angle for Canada only RSMI45 6DTC S45 In cold climate locations climates where temperatures will fall below 32 F 0 C we recommend that you use the insulated wall radia...

Страница 18: ...glass are maintained at hot temperatures see Refueling For Best Performance To clean the glass there are a number of specially designed cleaners Your authorized IHP dealer can recommend a suit able c...

Страница 19: ...SHT HT6103 6 dia 28 feet 8 54 m 29 feet 8 84 m DuraTech DTC 6 dia 28 feet 8 54 m 29 feet 8 84 m S 2100 HT6000 6 dia 18 feet 5 49 m 20 feet 6 1 m AC 6 dia 40 feet 12 19 m 50 feet 15 20 m Table 6 CHIMNE...

Страница 20: ...nstall the ASHT elbow on the top of the fireplace and using a level mark with an oval the location where the flue liner will enter the masonry chimney 2 In the middle of the oval drill a hole in the m...

Страница 21: ...dia 7B26ZE45 H8949 Telescopic length 8 dia 15 to 26 7B26ZLA H8950 Adjustable length 8 dia 2 5 7B26ZL2A H8951 Length two 2 feet 8KL2 H8954 Length one 1 feet 8KL1 H8953 Wall radiation shield 8 I D 7B26Z...

Страница 22: ...ron Log Retainer Bar PR SR2323 Gasket Kit Glass 69 1 x 5 16 steel and cast doors PR SR1823H Gasket Kit Steel Door Frame 73 5 8 dia PR SR1685D Gasket Kit Cast Door Frame 73 5 8 dia PR SR1823G Touch up...

Страница 23: ...Supports Offset Support SO Roof Support ST Roof Brace BS2 Firestops Firestop 6BF Radiation Shield 6RS Insulated Attic Radiation Shield 6RSA2 Insulated Wall Radiation Shield 6RSM Insulated Wall Radiat...

Страница 24: ...7B26ZR 7B26ZR Black grill with support 7B30ZO 7B30ZO Brass grill for 7B30ZK 7B30ZGB 7B30ZGB Length one 1 feet 8KL1 8KL1 Length two 2 feet 8KL2 8KL2 Length three 3 feet 8KL3 8KL3 Length four 4 feet 8KL...

Страница 25: ...may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high ef ciency EPA replaces are approved for burning dry seasoned...

Страница 26: ...ntact your IHP dealer for any questions or concerns REPLACEMENT PARTS See Page 22 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be orde...

Отзывы: