background image

IMPORTANT! GENERAL SAFETY 
PRECAUTIONS. READ AND 
UNDERSTAND THESE SAFETY 
RULES BEFORE YOUR FIRST FIRE.

       WARNING 

To avoid the risk of damaging 
fi replace materials and increas-
ing the risk of fi re, do not use the 
fi replace to cook or warm food.

       IMPORTANT 

When burning wood, use SOLID 
NATURAL  DRY WELL-SEASONED 
WOOD ONLY.  Hardwoods are rec-
ommended (soft woods tend to burn 
very quickly).  
• DO NOT burn treated wood, 
charcoal, coal, trash, cardboard, 
driftwood, woods dipped in tar, 
Christmas tree greens, pitch, pine 
tar, creosote, chemical chimney 
cleaners, fl ame colorants, poly-
styrene packaging, wood prod-
ucts with synthetic binders (i.e. 
plywood).  Plywood, lumber and 
other misc. materials can produce 
abnormally high temperatures, 
sputtering and smoking fi res and 
may contain hazardous chemicals 
to treat insects and fungus.
•  Burning unapproved fuels can 
produce excessive temperatures, 
beyond the design capabilities 
of the fi replace and may produce 
excess sparks or may contain 
hazardous chemicals.  Burning 
unapproved fuels can result in 
a chimney fire, a house fire, 
personal injury, death or loss of 
property.

 

       WARNING 

Never leave children unattended 
when there is a fi re burning in the 
fi replace.

       WARNING 

NEVER use gasoline, gasoline-
type lantern fuel, kerosene, 
charcoal lighter fl uid, naphtha, 
engine oil or similar liquids to 
start or “freshen up” a fi re in this 
fi replace. Keep any fl ammable 
liquids a safe distance from the 
fi replace at all times. 

       WARNING 

Use care when selecting window 
treatments for windows located 
near the fi replace.  Avoid using 
combustible flowing window 
treatments such as curtains on 
nearby windows that are of suf-
fi cient length to be blown in front 
of an open fl ame when the window 
is opened.  Keep any combustible 
furniture, materials or decorative 
pillows at least 48" (1219 mm) 
from the front fi replace opening.

       WARNING 

Never modify or alter your fi replace 
system in any way. To do so may 
create a potential fi re hazard and 
void the limited warranty

, listings 

and approvals of this system.

       WARNING 

Never leave your fi replace unat-
tended while it is burning.

       WARNING 

Always ensure that the air inlet to 
the fi replace is free from debris 
and any other obstructions that 
can block the entrance of air.

       WARNING 

Neither the manufacturer nor the 
seller warrants “smoke free” 
operation nor are we respon-
sible for inadequate system draft 
caused by mechanical systems, 
general construction conditions, 
inadequate chimney heights, 
adverse wind conditions and/or 
unusual environmental factors or 
conditions beyond our control. 

       IMPORTANT 

WHEN INSTALLED IN A MOBILE OR 
MANUFACTURED HOME:
• Mobile or manufactured home 
installations must be installed in 
accordance with the requirements 
of the Department of Housing and 
Urban Development (HUD) “Mobile 
Home Construction and Safety stan-
dards” for US or Canada Mortgage 
and Housing Corporation (CMHC) 
for Canada.
• The fi replace must be fastened to 
the fl oor by unfolding and screwing 
the small tabs on both sides at the 
bottom of the fi replace.   
• It is necessary to have access 
openings, for inspection purpose 
only, into built-in enclosures sur-
rounding the fi replace installation.  
Such openings to require a house-
hold tool for access.
• The vapor barrier of the mobile 
home shall be as close as possible 
of the location where the chimney 
assembly penetrates the ceiling 
and roof structure with no interfer-
ence to the required clearance to 
combustible material. 
• When the mobile or manufactured 
home has a fl at roof, the Attic Radia-
tion Shield  must be installed from 
below going through the roof (See 

Figures 22b and 22d)

.

• Warning: Do not install in a 
sleeping room.
•  Caution: The structural integrity 
of the manufactured home fl oor, 
wall, and ceiling/roof must be 
maintained.

    

  WARNING

The Montecito™ fi replace must 
be installed with an outside air 
kit intake, which is included with 
the fi replace

2

  WARNING

THE FIREPLACE MUST BE OPER-
ATED WITH THE DOORS FULLY 
OPENED OR DOORS FULLY CLOSED. 
IF THE DOORS ARE LEFT PARTLY 
OPENED, GAS AND FLAME MAY BE 
DRAWN OUT OF THE FIREPLACE 
OPENING, CREATING RISKS OF 
BOTH FIRE AND SMOKE.  IF THE 
UNIT IS OPERATED WITH THE 
DOORS FULLY OPENED, THE FIRE 
SCREEN MUST BE USED. 

 

  WARNING

THIS FIREPLACE HAS NOT BEEN 
TESTED WITH AN UNVENTED 
GAS   OR A FIREPLACE INSERT.  
TO REDUCE RIS K OF FIRE OR 
INJURY, DO NOT INSTALL AN 
UNVENTED GAS LOG SET OR 
FIREPLACE INSERT OR OTHER 
PRODUCTS NOT SPECIFIED FOR 
USE WITH THIS FIREPLACE.

Содержание montecito

Страница 1: ...doors Install this fireplace in a square and plumb condition using shims as necessary at sides and or bottom Install the fireplace only as described in these instructions This installation manual will...

Страница 2: ...ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the seller warrants smoke free operat...

Страница 3: ...ing Chimney lengths Elbows where necessary Associated components as per these installation instructions 6 diameterchimney ModelDuraTech DTC manufactured by DuraVent only including Chimney lengths Elbo...

Страница 4: ...g 10 to 20 minutes after reloading depending on the heat and on the moisture content of the wood Onceyouhavereachedthedesiredtemperature the air boost can be closed and the primary air set to a medium...

Страница 5: ...r Recommended Carbon Monoxide Poisoning Early signs of carbonmonoxidepoisoningaresimilartotheflu withheadaches dizzinessand ornausea Ifyou have these signs obtain fresh air immediately Somepeoplearemo...

Страница 6: ...NOTE The use of a firewood moisture meter is rec ommended to ensure the firewood contains less than 20 moisture Seasoning Guide Softwoods 6 months to 18 months Hardwoods 12 months to 24 months Logsth...

Страница 7: ...supplied will be necessary for this adjustment Checking Door Seal A one inch strip of paper may be used to perform a test of the integrity of the door seal Close the door on the paper in at least eigh...

Страница 8: ...ust cover the entire width of the fireplace The combustible floor in front of the fireplace must be covered with a non combustible ma terial tile marble stone etc See Figure 7 COLD CLIMATE INSTALLATIO...

Страница 9: ...instructions Product designs materials dimensions specifications colors and prices are subject to change or discontinuance without notice Allframingdimensionscalculatedfor 1 2 dry wall at the firepla...

Страница 10: ...hermal Barrier 8 Level 7 2 1 m Min 6 8 2 m Min 8 2 4 m Level 42 1067mm 2 x 3 Min 51mm x 76mm Rock Board or Other Noncombustible Facing Drywall NOTE It is recommended that the chase walls and floor be...

Страница 11: ...REPLACE BLOWER The fireplace comes equipped with a heat acti vated blower It is located in the bottom of the fireplace towards the back It uses 120V and must be connected to the main electrical circui...

Страница 12: ...a 5 diameter flexible pipe for the complete run up to thirty 30 feet and a 6 diameter pipe for a run of up to forty 40 feet The duct system must be installed respecting the following 1 Removetheplates...

Страница 13: ...Outside Intake Screw Opening Facing Down Wall Aluminum Tape Plastic Cover Insulation Flexible Pipe Aluminum Tape NOTE 2 clearancetocombustiblesaroundchimneycomponentsrequired NOTE Blown or fill type...

Страница 14: ...hing under the upper shingles and on top of the lower shingles Nail the flashing to the roof using roofing nails 6 Place the spacers and the storm collar over the flashing and tighten it with the bolt...

Страница 15: ...e a plumb bob to line up the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below...

Страница 16: ...6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm 95 3 4 2432 mm...

Страница 17: ...led Only one is required NOTE 45 angle for Canada only RSMI45 6DTC S45 In cold climate locations climates where temperatures will fall below 32 F 0 C we recommend that you use the insulated wall radia...

Страница 18: ...glass are maintained at hot temperatures see Refueling For Best Performance To clean the glass there are a number of specially designed cleaners Your authorized IHP dealer can recommend a suit able c...

Страница 19: ...SHT HT6103 6 dia 28 feet 8 54 m 29 feet 8 84 m DuraTech DTC 6 dia 28 feet 8 54 m 29 feet 8 84 m S 2100 HT6000 6 dia 18 feet 5 49 m 20 feet 6 1 m AC 6 dia 40 feet 12 19 m 50 feet 15 20 m Table 6 CHIMNE...

Страница 20: ...nstall the ASHT elbow on the top of the fireplace and using a level mark with an oval the location where the flue liner will enter the masonry chimney 2 In the middle of the oval drill a hole in the m...

Страница 21: ...dia 7B26ZE45 H8949 Telescopic length 8 dia 15 to 26 7B26ZLA H8950 Adjustable length 8 dia 2 5 7B26ZL2A H8951 Length two 2 feet 8KL2 H8954 Length one 1 feet 8KL1 H8953 Wall radiation shield 8 I D 7B26Z...

Страница 22: ...ron Log Retainer Bar PR SR2323 Gasket Kit Glass 69 1 x 5 16 steel and cast doors PR SR1823H Gasket Kit Steel Door Frame 73 5 8 dia PR SR1685D Gasket Kit Cast Door Frame 73 5 8 dia PR SR1823G Touch up...

Страница 23: ...Supports Offset Support SO Roof Support ST Roof Brace BS2 Firestops Firestop 6BF Radiation Shield 6RS Insulated Attic Radiation Shield 6RSA2 Insulated Wall Radiation Shield 6RSM Insulated Wall Radiat...

Страница 24: ...7B26ZR 7B26ZR Black grill with support 7B30ZO 7B30ZO Brass grill for 7B30ZK 7B30ZGB 7B30ZGB Length one 1 feet 8KL1 8KL1 Length two 2 feet 8KL2 8KL2 Length three 3 feet 8KL3 8KL3 Length four 4 feet 8KL...

Страница 25: ...may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high ef ciency EPA replaces are approved for burning dry seasoned...

Страница 26: ...ntact your IHP dealer for any questions or concerns REPLACEMENT PARTS See Page 22 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be orde...

Отзывы: