background image

Installation Accessories

Description

Cat./ Part No.

Facades 

(Required - Order Separately)

Montecito™ Facade Black, MFBK

H4843

Montecito Facade Hammered Steel, MFMC

H4845

Doors 

(Required - Order Separately)

Montecito Door, Black, MCBK

F1857

Montecito Door, Hammered Steel, MCMC

F1858

Cast Iron Door, Black, BWBK

F1859

Outside Air Kit

 

(included with fi replace)

Outside Air Coupler To Connect Outside Air (UZI) To Fire-
place, UZIAD

UZIAD

Outside Air Ducting - includes 4” insulated fl ex x 10’ long, UZI

UZI

Gravity Kit

Gravity kit: 

Complete double duct system includes: 2 elbows 

90º, 2 telescopic lengths, 2 grill supports and 2 black grills, 
2 fi replace adaptors, 7B30ZK-1

H8947

Gravity Kit Accessories

Elbow 90º, 8” dia., 7B26ZE90

H8948

Elbow 45º, 8” dia., 7B26ZE45

H8949

Telescopic length, 8” dia. (15” to 26”), 7B26ZLA

H8950

Adjustable length 8” dia (2” - 5”), 7B26ZL2A

H8951

Length two (2) feet, 8KL2

H8954

Length one (1) feet, 8KL1

H8953

Wall radiation shield, 8” I.D., 7B26ZR

H8952

OPTIONAL INSTALLATION ACCESSORIES

Fireplace Kits

Description

Cat./ Part No.

Rigid fi rescreen 

BUCEBWZN

Central Forced Air Kit Accessories 

Central Forced Air Kit, Central forced air kit including: blower 
(BISZY), fl ex adaptor (BISAF), 2 clamps, variable speed 
control (VRUW), thermo-disk (VTU), fan to fl exible pipe 
adapter (BISAVF), back draft damper (BISBD), aluminium 
tape, BISFWK-1

BISFWK-1

Flexible pipe 5” I.D. x  15 ft. Long, 5FLEX15

5FLEX15

Flexible pipe 5” I.D. x  30 ft. Long, 5FLEX25

5FLEX25

Heating and cooling thermostat, 24V, HCTW

HCTW



Not tested under EPA certifi cation. If installed, this appliance no 
longer qualifi es for EPA certifi cation. Check with local authorities 
having jurisdiction for requirements in your area.

21

Содержание montecito

Страница 1: ...doors Install this fireplace in a square and plumb condition using shims as necessary at sides and or bottom Install the fireplace only as described in these instructions This installation manual will...

Страница 2: ...ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the seller warrants smoke free operat...

Страница 3: ...ing Chimney lengths Elbows where necessary Associated components as per these installation instructions 6 diameterchimney ModelDuraTech DTC manufactured by DuraVent only including Chimney lengths Elbo...

Страница 4: ...g 10 to 20 minutes after reloading depending on the heat and on the moisture content of the wood Onceyouhavereachedthedesiredtemperature the air boost can be closed and the primary air set to a medium...

Страница 5: ...r Recommended Carbon Monoxide Poisoning Early signs of carbonmonoxidepoisoningaresimilartotheflu withheadaches dizzinessand ornausea Ifyou have these signs obtain fresh air immediately Somepeoplearemo...

Страница 6: ...NOTE The use of a firewood moisture meter is rec ommended to ensure the firewood contains less than 20 moisture Seasoning Guide Softwoods 6 months to 18 months Hardwoods 12 months to 24 months Logsth...

Страница 7: ...supplied will be necessary for this adjustment Checking Door Seal A one inch strip of paper may be used to perform a test of the integrity of the door seal Close the door on the paper in at least eigh...

Страница 8: ...ust cover the entire width of the fireplace The combustible floor in front of the fireplace must be covered with a non combustible ma terial tile marble stone etc See Figure 7 COLD CLIMATE INSTALLATIO...

Страница 9: ...instructions Product designs materials dimensions specifications colors and prices are subject to change or discontinuance without notice Allframingdimensionscalculatedfor 1 2 dry wall at the firepla...

Страница 10: ...hermal Barrier 8 Level 7 2 1 m Min 6 8 2 m Min 8 2 4 m Level 42 1067mm 2 x 3 Min 51mm x 76mm Rock Board or Other Noncombustible Facing Drywall NOTE It is recommended that the chase walls and floor be...

Страница 11: ...REPLACE BLOWER The fireplace comes equipped with a heat acti vated blower It is located in the bottom of the fireplace towards the back It uses 120V and must be connected to the main electrical circui...

Страница 12: ...a 5 diameter flexible pipe for the complete run up to thirty 30 feet and a 6 diameter pipe for a run of up to forty 40 feet The duct system must be installed respecting the following 1 Removetheplates...

Страница 13: ...Outside Intake Screw Opening Facing Down Wall Aluminum Tape Plastic Cover Insulation Flexible Pipe Aluminum Tape NOTE 2 clearancetocombustiblesaroundchimneycomponentsrequired NOTE Blown or fill type...

Страница 14: ...hing under the upper shingles and on top of the lower shingles Nail the flashing to the roof using roofing nails 6 Place the spacers and the storm collar over the flashing and tighten it with the bolt...

Страница 15: ...e a plumb bob to line up the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below...

Страница 16: ...6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm 95 3 4 2432 mm...

Страница 17: ...led Only one is required NOTE 45 angle for Canada only RSMI45 6DTC S45 In cold climate locations climates where temperatures will fall below 32 F 0 C we recommend that you use the insulated wall radia...

Страница 18: ...glass are maintained at hot temperatures see Refueling For Best Performance To clean the glass there are a number of specially designed cleaners Your authorized IHP dealer can recommend a suit able c...

Страница 19: ...SHT HT6103 6 dia 28 feet 8 54 m 29 feet 8 84 m DuraTech DTC 6 dia 28 feet 8 54 m 29 feet 8 84 m S 2100 HT6000 6 dia 18 feet 5 49 m 20 feet 6 1 m AC 6 dia 40 feet 12 19 m 50 feet 15 20 m Table 6 CHIMNE...

Страница 20: ...nstall the ASHT elbow on the top of the fireplace and using a level mark with an oval the location where the flue liner will enter the masonry chimney 2 In the middle of the oval drill a hole in the m...

Страница 21: ...dia 7B26ZE45 H8949 Telescopic length 8 dia 15 to 26 7B26ZLA H8950 Adjustable length 8 dia 2 5 7B26ZL2A H8951 Length two 2 feet 8KL2 H8954 Length one 1 feet 8KL1 H8953 Wall radiation shield 8 I D 7B26Z...

Страница 22: ...ron Log Retainer Bar PR SR2323 Gasket Kit Glass 69 1 x 5 16 steel and cast doors PR SR1823H Gasket Kit Steel Door Frame 73 5 8 dia PR SR1685D Gasket Kit Cast Door Frame 73 5 8 dia PR SR1823G Touch up...

Страница 23: ...Supports Offset Support SO Roof Support ST Roof Brace BS2 Firestops Firestop 6BF Radiation Shield 6RS Insulated Attic Radiation Shield 6RSA2 Insulated Wall Radiation Shield 6RSM Insulated Wall Radiat...

Страница 24: ...7B26ZR 7B26ZR Black grill with support 7B30ZO 7B30ZO Brass grill for 7B30ZK 7B30ZGB 7B30ZGB Length one 1 feet 8KL1 8KL1 Length two 2 feet 8KL2 8KL2 Length three 3 feet 8KL3 8KL3 Length four 4 feet 8KL...

Страница 25: ...may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high ef ciency EPA replaces are approved for burning dry seasoned...

Страница 26: ...ntact your IHP dealer for any questions or concerns REPLACEMENT PARTS See Page 22 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be orde...

Отзывы: