background image

Roof Down Slope Hole Size

SLOPE

ASHT+

*

 /

/ DuraTech DTC

**

S-2100+

*

 /

*

AC

*

Roof Pitch

6”

6”

6”

0 *

12-3/8” (314 mm)

14-1/8” (359 mm)

15”  (380 mm)

2/12

12-9/16” (319 mm)

14-3/8” (365 mm)

15-3/8”  (390 mm)

4/12

13” (330 mm)

14-7/8” (378 mm)

16-1/8”  (410 mm)

6/12

13-7/8” (352 mm)

15-3/4” (400 mm)

16-7/8”  (430 mm)

8/12

14-7/8” (378 mm)

17” (432 mm)

18-1/4”  (465 mm)

10/12

16-1/8” (410 mm)

18-3/8” (467 mm)

19-5/8”  (500 mm)

12/12

17-1/2” (445 mm)

20” (508 mm)

21-3/8”  (545 mm)

 

*

  Cross Slope Hole Size

  Put the chimney cap into place.       
  Wash the roof fl ashing with a solvent or vinegar, then paint it with rust-proof paint.

Table 3 

Figure 24

Figure 25

Minimum Chimney Height Using Elbows

Fireplace Model

MONTE

Chimney Model

ASHT+

*

 / S2100+

*

 /

*

 /

*

 / AC

*

 / DuraTech DTC

**

Vertical installation

12 feet (3.66 m)

Two (2) elbows

15 feet (4.57 m)

Four (4) elbows

17 feet (5.18 m)

Table 4

After reaching the location requiring the 
elbow, proceed as follows:

ASHT+

*

 /

*

 / S-2100+

*

 /

DuraTech DTC

**

  Chimneys

1.  Install the fi rst elbow; turn it in the required 

direction.  Fasten it to the chimney with 
the three (3) 1/2” (12 mm) metal screws 
provided with the elbow.

2. Install the necessary chimney lengths to 

achieve the required offset.  Lock the chimney 
lengths together: it is recommended to use 
three (3) 1/2” (12 mm) screws.  If the offset 
length is made of two (2) chimney lengths or 
more, use an offset or roof support halfway 
up the offset.  If penetrating a wall, install 
a wall radiation shield (see

 Figures 27 and 

29

).

3. Use another elbow to turn the chimney 

vertically.  Secure the elbow, using three 
(3) 1/2” (12 mm) screws (provided with the 
elbow).

4. Use a plumb-bob to line up the center of 

the hole. Cut a hole for the chimney in the 
ceiling/fl oor.  Frame this hole as described 
previously (refer to section 

Chimney Instal-

lation Instructions

).

5. From below, install a fi restop (See

 Figure 

22a

).

6. A support (ST

*

 or SO

*

) must be used on 

the fi rst 15’ section (5 m).

7.  Continue with the regular installation.

AC Chimney 

*

1.  Install the fi rst elbow.  Turn it in the required 

direction.  To lock it in place, turn 1/8 of a 
turn.  Fasten the straps attached to the elbow 
to the surrounding frame, using nails or 
drywall screws (see 

Figure 27

).

2. Install the necessary chimney lengths to 

achieve the required offset.  Lock the chimney 
lengths together.  If penetrating a wall, use 
a wall radiation shield.

3. Use another elbow to turn the chimney 

vertically.  Lock it to the chimney.  Fasten 
the straps attached to the elbow to the 
surrounding framing using nails or drywall 
screws.

4.  Use a plumb-bob to line up the center of the 

hole.  Cut a hole for the chimney in the ceiling.  
Frame this hole as described previously.

5. From below, install a fi restop (see 

Figure 

22c

).

6.  Continue with the regular installation.

NOTE: When using AC

*

 chimney, an AC6SB

*

 

starter section must be used before installing 
an elbow.  When an offset is needed imme-
diately off the top of the fi replace, an elbow 
starter section, AC6SB30

*

, is available.

AC 

*

Air Cooled Chimney

Collar

Chimney

Flashing

OFFSET CHIMNEY INSTALLATION

After reaching the location requiring the elbow, proceed as follows. The minimum chimney height 
when using elbows is:

Spacer (built 

into fl ashing)

NOTES:
• 

Must return to vertical before penetrating ceiling or fl oor.

• 

A maximum of 2 offsets are allowed.

*

Available from Security Chimneys™ 

**

Available from DuraVent

®

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

15

Содержание montecito

Страница 1: ...doors Install this fireplace in a square and plumb condition using shims as necessary at sides and or bottom Install the fireplace only as described in these instructions This installation manual will...

Страница 2: ...ensure that the air inlet to the fireplace is free from debris and any other obstructions that can block the entrance of air WARNING Neither the manufacturer nor the seller warrants smoke free operat...

Страница 3: ...ing Chimney lengths Elbows where necessary Associated components as per these installation instructions 6 diameterchimney ModelDuraTech DTC manufactured by DuraVent only including Chimney lengths Elbo...

Страница 4: ...g 10 to 20 minutes after reloading depending on the heat and on the moisture content of the wood Onceyouhavereachedthedesiredtemperature the air boost can be closed and the primary air set to a medium...

Страница 5: ...r Recommended Carbon Monoxide Poisoning Early signs of carbonmonoxidepoisoningaresimilartotheflu withheadaches dizzinessand ornausea Ifyou have these signs obtain fresh air immediately Somepeoplearemo...

Страница 6: ...NOTE The use of a firewood moisture meter is rec ommended to ensure the firewood contains less than 20 moisture Seasoning Guide Softwoods 6 months to 18 months Hardwoods 12 months to 24 months Logsth...

Страница 7: ...supplied will be necessary for this adjustment Checking Door Seal A one inch strip of paper may be used to perform a test of the integrity of the door seal Close the door on the paper in at least eigh...

Страница 8: ...ust cover the entire width of the fireplace The combustible floor in front of the fireplace must be covered with a non combustible ma terial tile marble stone etc See Figure 7 COLD CLIMATE INSTALLATIO...

Страница 9: ...instructions Product designs materials dimensions specifications colors and prices are subject to change or discontinuance without notice Allframingdimensionscalculatedfor 1 2 dry wall at the firepla...

Страница 10: ...hermal Barrier 8 Level 7 2 1 m Min 6 8 2 m Min 8 2 4 m Level 42 1067mm 2 x 3 Min 51mm x 76mm Rock Board or Other Noncombustible Facing Drywall NOTE It is recommended that the chase walls and floor be...

Страница 11: ...REPLACE BLOWER The fireplace comes equipped with a heat acti vated blower It is located in the bottom of the fireplace towards the back It uses 120V and must be connected to the main electrical circui...

Страница 12: ...a 5 diameter flexible pipe for the complete run up to thirty 30 feet and a 6 diameter pipe for a run of up to forty 40 feet The duct system must be installed respecting the following 1 Removetheplates...

Страница 13: ...Outside Intake Screw Opening Facing Down Wall Aluminum Tape Plastic Cover Insulation Flexible Pipe Aluminum Tape NOTE 2 clearancetocombustiblesaroundchimneycomponentsrequired NOTE Blown or fill type...

Страница 14: ...hing under the upper shingles and on top of the lower shingles Nail the flashing to the roof using roofing nails 6 Place the spacers and the storm collar over the flashing and tighten it with the bolt...

Страница 15: ...e a plumb bob to line up the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below...

Страница 16: ...6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm 95 3 4 2432 mm...

Страница 17: ...led Only one is required NOTE 45 angle for Canada only RSMI45 6DTC S45 In cold climate locations climates where temperatures will fall below 32 F 0 C we recommend that you use the insulated wall radia...

Страница 18: ...glass are maintained at hot temperatures see Refueling For Best Performance To clean the glass there are a number of specially designed cleaners Your authorized IHP dealer can recommend a suit able c...

Страница 19: ...SHT HT6103 6 dia 28 feet 8 54 m 29 feet 8 84 m DuraTech DTC 6 dia 28 feet 8 54 m 29 feet 8 84 m S 2100 HT6000 6 dia 18 feet 5 49 m 20 feet 6 1 m AC 6 dia 40 feet 12 19 m 50 feet 15 20 m Table 6 CHIMNE...

Страница 20: ...nstall the ASHT elbow on the top of the fireplace and using a level mark with an oval the location where the flue liner will enter the masonry chimney 2 In the middle of the oval drill a hole in the m...

Страница 21: ...dia 7B26ZE45 H8949 Telescopic length 8 dia 15 to 26 7B26ZLA H8950 Adjustable length 8 dia 2 5 7B26ZL2A H8951 Length two 2 feet 8KL2 H8954 Length one 1 feet 8KL1 H8953 Wall radiation shield 8 I D 7B26Z...

Страница 22: ...ron Log Retainer Bar PR SR2323 Gasket Kit Glass 69 1 x 5 16 steel and cast doors PR SR1823H Gasket Kit Steel Door Frame 73 5 8 dia PR SR1685D Gasket Kit Cast Door Frame 73 5 8 dia PR SR1823G Touch up...

Страница 23: ...Supports Offset Support SO Roof Support ST Roof Brace BS2 Firestops Firestop 6BF Radiation Shield 6RS Insulated Attic Radiation Shield 6RSA2 Insulated Wall Radiation Shield 6RSM Insulated Wall Radiat...

Страница 24: ...7B26ZR 7B26ZR Black grill with support 7B30ZO 7B30ZO Brass grill for 7B30ZK 7B30ZGB 7B30ZGB Length one 1 feet 8KL1 8KL1 Length two 2 feet 8KL2 8KL2 Length three 3 feet 8KL3 8KL3 Length four 4 feet 8KL...

Страница 25: ...may burn at excessive temperatures and may cause damage to the Product or may cause it to function improperly IHP stoves inserts and high ef ciency EPA replaces are approved for burning dry seasoned...

Страница 26: ...ntact your IHP dealer for any questions or concerns REPLACEMENT PARTS See Page 22 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be orde...

Отзывы: