NOTE: DIAGRAMS & ILLUSTRATION ARE NOT TO SCALE.
12
OPTIONAL EQUIPMENT
Blower Kits
The FBK-100 Blower Kits are used when a
wall-mounted ON/OFF blower switch is desired,
and the FBK-200 Blower Kits are used when a
wall-mounted variable speed blower control
(rheostat) is desired. NOTE: A Junction Box
is provided.
The blower is installed beneath the firebox.
Room air is drawn in through the side slots
of the fireplace, heated as it passes across the
firebox, and discharged through the upper area
of the firebox opening.
The installation instructions for installing these
blower kits are on Pages 12 through 14. Also
see the installation instructions provided with
the blower kits (Form #750028M). For electrical
requirements, refer to Figures 13, 14 and 15.
If the blower kit is to be installed at the time of
installation or at a later date, the main power
supply must be installed at the time of instal-
lation. This will require that the electrical
connections must be made BEFORE the firebox
is framed and enclosed in the finished walls.
Route a 3-wire, 120 VAC, 60 Hz, 1 ph power
supply and connect to electrical receptacle wires
and wall switch or rheostat.
Grounded
to Appliance
Blower Motor
Motor Plug
Receptacle
120V
Appliance Junction Box
NOTE: If any of the original wire as supplied
must be replaced, it must be replaced with type
AWM 105
°
c – 18Ga. wire
Blower
* Junction Box
Bend blower mounting
tabs up to secure
blower in place
* Electrical Outlet
Tie a loose knot in power
cord to take up slack
Top View
Figure 14
Figure 13
NOTE: If any of the original wire as supplied must
be replaced, it must be replaced with type AWM
105 degree C - 14 gage wire.
* The Junction Box / Electrical Kit is not included.
See Page 15 for ordering information.
IMPORTANT
The Ground Lead must be connected
to the green screw (located on the
junction box). Failure to do this
could result in an electrical short or
shock injury.
The appliance must be electrically
grounded in accordance with local
codes or, in the absence of local
codes, the national electrical code,
ANSI/NFPA 70-latest edition. (In
Canada, the current CSA C22.1
Canadian Electrical Code).
CAUTION
Electrical connections should
only be performed by a qualified,
licensed electrician. Main power
must be off when connecting to
main electrical power supply or
performing service.
Figure 12
Hood
Side View
CAUTION: Label all wires prior to dis-
connection when servicing controls. Wiring
errors can cause improper and dangerous
operation. Verify proper operation after
servicing.
120V, 60HZ,
1PH BLOWER
CONTROL CIRCUIT
WIRING
Junction
Box
Factory Wired
Blower
Tab
Intact
Plug blower
into this
receptacle
Ground - Green
* Wall-mounted ON/
OFF Blower Switch
or Variable Speed
Control Switch.
Ground
HOT SIDE OF
RECEPTACLE
*An ON/OFF Wall Switch is used with the FBK-100 kit
(field provided or sold separately - order P/N 85L87);
A Variable Speed Control (provided) is used with the
FBK-200 kit. The installation of these kits also require
a Junction Box / Electrical Kit (provided).
NOTE: If any of the original wire as supplied must
be replaced, it must be replaced with type AWM 105
degree C - 14 gage wire.
Neutral - White
120 V
AC Black
Green
Ground
Screw
NEUTRAL
SIDE OF
RECEPTACLE
Black
Field Wired
Figure 15
Plug-in Electronic Burner
Assembly (sold separately)
into this receptacle