background image

3

Misc. Codes / Standards - 

The Installation must conform to local codes 

or, in the absence of local codes, with the 

National Fuel Gas Code, ANSI Z223.1/NFPA 

54 - latest edition.

The appliance, when installed, must be electri-

cally grounded in accordance with local codes or, 

in the absence of local codes, with the National 

Electrical Code, ANSI/NFPA 70 - latest edition.

Check the packaging list to be sure that you 

have all the necessary parts in usable condition. 

Also check for concealed damage.

Tools and Building Supplies

Normally Required

Tools Should Include:

•  Phillips screwdriver

• Hammer

•  Saw and/or sabersaw

• Level

•  Measuring tape

•  Electric drill and bits

• Pliers

• Square

•  Piping complying with local codes

•  Pipe wrench

•  Tee joint 

•  Pipe compound

Building Supplies Should Include:

•  Framing materials

•  Wall finishing materials

•  Caulking materials 

(noncombustible)

•  Fireplace surround materials 

   

(noncombustible)

• Insulation

 

(for packing around gas-line penetration holes)

Codes

Adhere to all local codes or in their absence 

the latest edition of The National Fuel Gas Code 

ANSI Z223.1 or NFPA 54 - latest edition which 

can be obtained from The American National 

Standards Institute, Inc. (25 West 43rd Street, 

4th floor New York, NY 10036) or National Fire 

Protection Association, Inc. (1 Batterymarch 

Park Quincy, MA 02169-7471).

TABLE OF CONTENTS

Important Safety Information ........... Page 2

Packaging List .................................. Page 3

General Information ......................... Page 3

Burn-in Period .................................. Page 3

Tools/Building Supplies .................... Page 3

Codes ............................................... Page 3

Combustion And Ventilation Air ....... Page 4

Cold Climate Insulation .................... Page 5

Requirements for the 

   Commonwealth of Massachusetts Page 5

Location Of Firebox .......................... Page 6

Clearances ....................................... Page 6

Assembly Steps ............................... Page 8

Gas Line Installation ......................... Page 8

Firebox Framing ............................... Page 9

Firebox Installation ........................... Page 9

Specifications ................................... Page 10

Framing Specifications ..................... Page 11

Hood Installation .............................. Page 11

Optional Equipment / Blower Kit 

     Installation .................................. Page 12

Firebox Finishes ............................... Page 15

Accessories/components ................. Page 15

Replacement Parts List .................... Page 17 

Warranty .......................................... Page 19

This installation manual will help you obtain 

a safe, efficient, dependable installation for 

your appliance and vent system. 

PLEASE READ AND UNDERSTAND 

THESE INSTRUCTIONS BEFORE BEGIN-

NING YOUR INSTALLATION.

Packaging List

Vent-Free Gas Firebox

Hood

  (optional for models Atlas36ZP2, Atlas36ZP3, 

Atlas42ZP2 and Atlas42ZP3)

Installation and Operation Instructions

 

GENERAL INFORMATION

These Vent-Free firebox enclosures are designed 

to accept all ANSI Z21.11.2 approved Decorative 

Type Vent-Free Gas Log Room Heaters.  For the 

appropriate Vent-Free Gas Log Room Heater 

model, refer to Page 16 (see 

Vent-Free Gas Log 

Sets)

.  Refer to the installation instructions pro-

vided with the log sets for detailed instructions.

This installation manual along with the vent-free 

gas log installation manual will enable you to 

obtain a safe, efficient and dependable instal-

lation of your room heater system.

Do not alter or modify the firebox or its 

com ponents under any circumstances. Any 

modification or alteration of the firebox system, 

including but not limited to the firebox and ac-

cessories, may void the warranty, listings and 

approvals of this system and could result in an 

unsafe and potentially dangerous installation.

These Built-In Vent-Free Fireboxes have been 

tested and approved as Ventless Firebox Enclo-

sures for Gas-Fired Unvented Decorative Room 

Heaters to ANSI Z21.91.

Burn-in Period

During the first few times of operation of this 

appliance there will be some odor due to the 

curing of the paint and burning off of lubricants 

used in the manufacturing process. We recom-

mend that you open windows and ventilate the 

house during the initial burns. The paint emits 

non-toxic odors during this process.

Depending on your use, the burn-in period may 

take a few hours or a few days.  

KEEP YOUR HOUSE WELL VENTILATED 

DURING THE BURN-IN PERIOD.  THE ODOR 

AND HAZE EMITTED DURING THE BURN-IN 

PERIOD CAN BE QUITE NOTICEABLE AND MAY 

SET OFF A SMOKE DETECTOR.

If an optional blower is installed, Do not turn it 

on during the Burn-In period. 

CONGRATULATIONS!

In selecting this Astria

®

 Vent-Free Gas Firebox you have chosen the finest and most 

dependable fireplace to be found anywhere.  A beautiful, prestigious, alternative to a 

wood burning fireplace.  Welcome to a family of tens of thousands of satisfied Astria 

Fireplace Owners.

Please read and carefully follow all of the instructions found in this manual.  Please pay 

special attention to the safety instructions provided in this manual.  The Homeowner's 

Care and Operation Instructions included here will assure that you have many years of 

dependable and enjoyable service from your Astria product.

Содержание Atlas36ZP2

Страница 1: ...IREBOX MEETS THE MINIMUM DIMENSIONS REQUIREDFORTHEINSTALLATIONS THIS IS A VENT FREE GAS FIRED HEATER ENCLO SURE IT USES AIR OXYGEN FROM THE ROOM IN WHICH IT IS INSTALLED PROVISIONS FOR ADEQUATE COMBUSTION AND VENTILATION AIR MUST BE PROVIDED REFER TO COMBUSTION AND VENTILATION AIR SECTION PAGES 3 4 INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference FOR ...

Страница 2: ...alified service person The heater should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpet ing bedding material etc It is important that control compart ments burners and circulating air passageways of the heater be kept clean Allow the heater to cool before servicing Always shut off any electrici...

Страница 3: ...ckaging List Vent Free Gas Firebox Hood optional for models Atlas36ZP2 Atlas36ZP3 Atlas42ZP2 and Atlas42ZP3 Installation and Operation Instructions GENERAL INFORMATION TheseVent Freefireboxenclosuresaredesigned toacceptallANSIZ21 11 2approvedDecorative TypeVent FreeGasLogRoomHeaters Forthe appropriate Vent Free Gas Log Room Heater model refer to Page 16 see Vent Free Gas Log Sets Refer to the inst...

Страница 4: ...as a space whose volume is less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu per hour 4 8 m3 per kw of the aggregate input rating of all appliances installed in that space Rooms com municating directly with the space in whic...

Страница 5: ...m heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit Not to Scale Figure 1 CAUTION Do not install in the vicinity where gasoline or other flammable liq uids may be stored The Vent Free firebox must be kept clear and free from these combustible materials WARNING Do not use a blower insert heat exchanger insert or other acces sory not approved for use with this applia...

Страница 6: ...commend the use of high temperature paint rated 175 F or higher on the hood and the underside of the mantel Clearances Ensure the minimum clearances shown in Figures 2 through 6 are maintained Left and right clearances are determined when facing the front of the firebox Follow these instructions carefully to ensure safe installation Failure to follow these requirements may create a fire hazard Com...

Страница 7: ...ea above Models Atlas36ZP2 and Atlas42ZP2 WITH Hood Installed Hood is optional on these models 16 9 1 2 2 3 4 5 6 10 11 12 13 14 15 Top of Firebox Opening Screen Top of Appliance Combustible Mantel and Trim Header Top Spacer on Appliance Safe Zone Hood Non Combustible Material 3 Min Example Example Coordinate in Example Combustible Material wall 23 24 16 6 7 8 10 9 17 18 19 20 21 22 Top of Firebox...

Страница 8: ...unique however and might require a different sequence Step 1 Position firebox prior to framing or into prepared framing Step 2 Field wire the main power supply to the appliance if a blower kit is to be installed at the time of installation or a later date An optional junction box kit and blower kit is re quired seePage15 for ordering information Followtheinstallationandwiringinstructionson Pages 1...

Страница 9: ...ways be measured from a finished surface If a wall covering such as drywall is to be attached to the rear wall then the depth must be measured from the drywall surface It is important that this dimension be exact Step 2 Level the firebox by checking the top edge of the firebox Shim if necessary Step 3 Fireplace should be secured to side framing members using the full length nailing tabs at the top...

Страница 10: ...2 Atlas36ZP3 200 lbs 22 Cu Ft F0393 Atlas42ZP2 230 lbs 26 Cu Ft F0394 Atlas42ZP3 230 lbs 26 Cu Ft A hood is optional for models Atlas36 Series and Atlas42 Series Dimensions Inches millimeters Model No A B C D E F G H J K L M N P Q Atlas36 Series 36 914 28 711 41 3 4 1061 41 1 4 1048 23 1 2 597 20 508 3 76 8 3 8 213 15 7 8 403 7 1 2 190 12 305 1 3 8 35 5 1 2 140 34 3 8 873 33 5 8 854 Atlas42 Series...

Страница 11: ... sure hood is level and secure Step 3 Reinstall screen and rod assemblies see Figure 11 Framing Dimensions Opening Atlas36 Series Atlas42 Series A 42 1 4 1073 48 1 4 1226 B 44 1 4 1124 44 1 4 1124 C 23 5 8 600 29 5 8 753 D 11 1 4 286 14 1 4 362 E 63 1 2 1613 69 1 2 1765 F 31 3 4 807 34 3 4 883 G 20 1 2 521 20 1 2 521 H 44 1 4 1124 49 1 8 1248 Table 1 This Table corresponds to Figures 8 9 10 Rough ...

Страница 12: ...wire as supplied must be replaced it must be replaced with type AWM 105 degree C 14 gage wire The Junction Box Electrical Kit is not included See Page 15 for ordering information IMPORTANT TheGroundLead mustbeconnected to the green screw located on the junction box Failure to do this could result in an electrical short or shock injury The appliance must be electrically grounded in accordance with ...

Страница 13: ...hat the tabs located on the cabinet base are seated in the notches of the blower bracket Bend the tabs over to secure the blower assembly see Figure 22 Step 5 Plug power cord into the electrical outlet as illustrated in Figure 14 Models Atlas36ZP2 Atlas36ZP3 Atlas42ZP2 and Atlas42ZP3 J Box Flanges J Box Electrical Outlet Right Outside Cabinet Panel Wires Figure 16 Figure18 Model Atlas42ZP2Shown Fi...

Страница 14: ...tlas42ZP3 Shown Loose knot in power cord to take up slack Firebox floor Model Atlas42ZP2 Shown Model Atlas42ZP2 Locating Tabs Bend Locating Tabs Over into notches Use screw provided and secure in place as shown The notched side of cover plates goes inside firebox panel Screw Cover Plate Right Side Panel of Firebox Figure 23 Installing J box Cover Plate All Models Step 9 Follow the instructions bel...

Страница 15: ...earth Extension combustibles allowed No carpet or vinyl Combustible Platform SIDE VIEW Firebox Floor Combustible Wall Figure 24 Raised Hearth Extension Fireplace Opening From Base to Bottom of Firebox Opening floor 5 3 4 Max Base APPROVED ACCESSORIES AND COMPONENTS Decorative Volcanic Stone Thedecorativevolcanicstone ModelFDVS can be used to enhance the look of your appliance Order model FDVS for ...

Страница 16: ... switch Touch Up Paint Kit Repair of minor scratches and discoloration of the appliance black painted surfaces may be accomplished with the touch up paint kit PA I N T The variable speed control rheostat is included with FBK 200 models only AnON OFFwallswitchcanbeused with the FBK 100 models field supplied or order P N 85L87 Wall Switch Kit shown below ON OFF Wall Switch Kit The ON OFF wall switch...

Страница 17: ...ing repair parts always give the following information 1 The model number of the firebox 2 The serial number of the firebox 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the firebox NOTE The model and serial number can be found on the rating label located on the bottom left front corner of the appliance If you encounter any problems or have any ...

Страница 18: ...________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Страница 19: ... fire flood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal use The Product is designed to burn either natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive te...

Страница 20: ...HP reserves the right to make changes at any time without notice in design materials specifications prices and the discontinuance of colors styles and products Consult your local distributor for fireplace code information 1769 East Lawrence Street Russellville AL 35654 P900238 00 ...

Отзывы: