Installation
900921-00E, 06/2019
Innovative Hearth Products
Aries™ -C Series Direct-Vent Gas Fireplaces
39
TP-TH
TP
TH
APPLIANCE- MOUNTED
ON/OFF SWITCH
(OPTIONAL)
BK/W(1)
BK/W(1)
WALL-MOUNTED ON/OFF SWITCH (OPTIONAL)
THERMOSTAT (OPTIONAL)
THERMOPILE
GAS VALVE
JUNCTION BOX
BLACK
W
GR
120 V
AC
WALL MOUNTED CONFIGURATION FOR FAN SWITCH (OPTIONAL)
BK
R
FAN
(OPTIONAL)
Figure 29 - Wiring Diagram - Millivolt Gas Valves
1.
If installing an ON/OFF wall switch or thermostat, mount it in a convenient location on a wall near the fireplace.
2.
Wire the control switch within the millivolt control circuit using the 15 ft of 2-conductor wire supplied with the
unit
(
Figure 31
).
NOTE:
The supplied 15 ft of 2-conductor wire has one end of each conductor connected to the gas valve circuit and
the other end of each conductor placed loose inside the bottom compartment.
CAUTION
In millivolt systems, do NOT connect a wall switch to a 120 V power supply.