8.
Install the Vent Restrictor (if necessary)
1.
Use the vent run descriptions in
Figure 12
to determine if a vent restrictor is necessary.
2.
If necessary, assemble the vent restrictor and wing as detailed in
Figures 12
and
13C
.
3.
If necessary, install the appropriate vent restrictor
(
Figure 13A or 13B
).
NOTE:
If installing the vent restrictor in a rear vent application, ensure the factory-installed intake air baffle is in place
(
Figure 13B
)
.
NOTE:
The vent restrictor is shipped in the firebox.
Figure 12 - When to use a vent restrictor
2 1/2”
Break-Away
1
3
20
40
6
10
40
25 ft Maximum
horizontal run (flat to near level)
60 ft Maximum vertical run
60
1.9
25
Horizontal Distance (ft)
Vertical Height (ft) from top of unit
Vertical Height (ft)
2
5
Elbow**
5
10
15
3” Base + wing
3” Base
6 ft Minimum
vertical run
6 ft Minimum vertical run
None
*
*
* For straight runs or runs with elbows as illustrated in Vertical Vent Figures/Tables starting on
Page 29
** No rise required.
Vent Restrictor with Vertical Terminations
When vertically terminating the vent system through the roof and using the vent restrictor, install the vent restrictor
in the top vent of the fireplace outlet.
If installing more than 6 ft of vertical venting, install the restrictor
(
Figure 13A
),
from inside or outside the unit, in the
inner fireplace collar. The vent restrictor is held in place by friction.
Vent Restrictor with Horizontal Terminations
When horizontally terminating a vent system with a vertical vent run up to 4 ft through an exterior wall, no vent
restrictor is required.
If installing more than 6 ft of vertical venting, install the restrictor
(
Figure 13B
),
from inside or outside the unit, in the
inner fireplace collar. The vent restrictor is held in place by friction.
NOTE
: Use base vent restrictor with breakaway portion raised when rear venting with only a slip collar and a
termination.
Figure 13A - Vent restrictor installation, Top vent
U-Shaped Vent
Restrictor
Inner
Fireplace
Collar
Appliance Top Vent Outlet
Figure 13B - Vent restrictor installation, Rear vent
Figure 13C - Vent restrictor assembly
With break-away
raised***
Base Vent Restrictor
Base Vent Rest Wing
Base Vent Rest Wing
With break-away
raised***
Inner Fireplace Collar
Appliance Rear
Vent Outlet
U-Shaped Vent
Restrictor
Intake Air Baffle