![Astria Fireplaces Aries C Series Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/astria-fireplaces/aries-c-series/aries-c-series_installation-and-operation-instructions-manual_2990881040.webp)
Installation
900921-00E, 06/2019
Innovative Hearth Products
Aries™ -C Series Direct-Vent Gas Fireplaces
40
Green
Ground
Screw
Black
Hot Side of
Receptacle
Tab Intact
Tab
Broken
Green
White
Neutral
Side of
Receptacle
120 VAC - Black
Neutral - White
Ground - Green
J-BOX / RECEPTACLE
WIRING 120V, 60HZ, 1PH
Junction Box
Field Wired
Factory Wired
(Power
Supply
Unswitched)
12.
Connect the Gas Line
All codes require a shutoff valve mounted in the supply line.
Figure 31, Page 41
illustrates two methods for
connecting the gas supply. The flex-line method is acceptable in the U.S., however, Canadian requirements vary
depending on locality. Installation must be in compliance with local codes.
Figure 30 - Wiring Diagram—Junction Box
Red
NOTE:
A sediment trap is recommended in the gas piping within the home to prevent moisture and debris in the line
from damaging the valve.
NOTE:
Secure all joints tightly using appropriate tools and sealing compounds (ensure propane resistant compounds
are used in propane applications). Seal around the gas line to prevent cold air leakage. Gas line holes and other
openings can be caulked or stuffed with unfaced fiberglass insulation.
Figure 31 - Gas Line Connection
(Optional) flexible gas line
connector
Gas valve
3/8” Nipple
3/8” Union
3/8” Close nipple
3/8” Shutoff valve
3/8 NPT x 3/8” Flare
fitting
1/2 x 3/8” Flare
shutoff valve
3/8” Flex tubing
Gas stub
1/2 x 3/8”
Reducer
These fireplaces are equipped with a gas flex line for use (where permitted) in connecting the unit to the gas line. A
gas flex line is provided to aid in attaching the direct-vent fireplace to the gas supply. The gas flex line can only be
used where local codes permit. The flex line is rated for both natural and propane gas. A manual shut off valve is
also provided with the flex line.
The gas control valve is located in the lower control compartment
(
Figure 1, Page 9
)
.