Functio
n code
Name
Detailed instruction of parameters
Defaul
t value
Modify
setting
P05.52
Upper limit
frequency
of HDI
P05.50~50.000kHz
50.000
kHz
○
P05.53
Correspondi
ng setting
of upper
limit
frequency
of HDI
-100.0%~100.0%
100.0%
○
P05.54
HDI
frequency
input filter
time
0.000s~10.000s
0.100s
○
P06 Group Output terminals
P06.01
Y1 output
selection
0:Invalid
1:In operation
2:Forward rotation operation
3:Reverse rotation operation
4: Jogging operation
5:The inverter fault
6:Frequency degree test FDT1
7:Frequency degree test FDT2
8:Frequency arrival
9:Zero speed running
10:Upper limit frequency arrival
11:Lower limit frequency arrival
12:Ready for operation
13:Pre-magnetizing
14:Overload pre-alarm
15: Underload pre-alarm
16:Completion of simple PLC stage
17:Completion of simple PLC cycle
18:Setting count value arrival
19:Defined count value arrival
20:External fault valid
21: Reserved
22:Running time arrival
23:MODBUS communication virtual terminals
output
24~25:Reserved
26: Establishment of DC bus voltage
27~30:Reserved
0
P06.03
Relay RO1
output
selection
1
○
P06.04
Relay RO2
output
selection
5
○
P06.05
Polarity
selection of
output
The function code is used to set the pole of the
output terminal.
When the current bit is set to 0, input terminal
0
○