Astraada DRV-24 frequency inverters Function Parameters
73
Functio
n code
Name
Detailed instruction of parameters
Defaul
t value
Modify
P10.21
The running
time of
stage 9
S4 OFF OFF OFF OFF OFF OFF OFF OFF
step 0
1
2
3 4 5 6 7
S1 OFF ON OFF ON OFF ON OFF ON
S2 OFF OFF ON ON OFF OFF ON ON
S3 OFF OFF OFF OFF ON ON ON ON
S4 ON ON ON ON ON ON ON ON
step 8
9
10 11 12 13 14 15
Setting range of P10.(2n,1<n<17):
-100.0~100.0%
Setting range of P10.(2n+1,
1<n<17):0.0~6553.5s(min)
0.0s
○
P10.22
Multi-step
speed 10
0.0%
○
P10.23
The running
time of
stage 10
0.0s
○
P10.24
Multi-step
speed 11
0.0%
○
P10.25
The running
time of
stage 11
0.0s
○
P10.26
Multi-step
speed 12
0.0%
○
P10.27
The running
time of
stage 12
0.0s
○
P10.28
Multi-step
speed 13
0.0%
○
P10.29
The running
time of
stage 13
0.0s
○
P10.30
Multi-step
speed 14
0.0%
○
P10.31
The running
time of
stage 14
0.0s
○
P10.32
Multi-step
speed 15
0.0%
○
P10.33
The running
time of
stage 15
0.0s
○
P10.34
Simple PLC
0~7 stage
ACC/DEC
time
selection
Below is the detailed instruction:
Functio
n code
Binary bit Step
ACC/
DEC
0
ACC/
DEC
1
ACC/
DEC
2
ACC/
DEC
3
P10.34
BIT1 BIT0 0
00 01 10 11
BIT3 BIT2 1
00 01 10 11
BIT5 BIT4 2
00 01 10 11
BIT7 BIT6 3
00 01 10 11
BIT9 BIT8 4
00 01 10 11
BIT1 BIT1
5
00 01 10 11
0x0000
○
P10.35
Simple PLC
8~15 stage
ACC/DEC
time
selection
0x0000
○