41
Stage
Issues, symptoms
Additional info
Likely Cause
Solution
Peeling
“Arm misaligned – realign”
is displayed.
Peeling action does
not start.
The Arm is not in the correct
start position.
Return the arm to the start-
ing position, and press
“Start.”
Skin remains after peeling
The skin peels off
in a striped pattern.
The peeling thickness setting
is incorrect.
Making the peeling adjust-
ment thicker will prevent
striping.
Concave portion
unpeeled
The blade cannot peel con-
tours that are too deep.
This is normal. An example
of this is a peach with a
vertical side grooves.
The peeling thickness or spin
speed setting is incorrect.
Increase the peeling
thicknes, and slow the spin
speed to leave less peel.
Skin remains after peeling
Targeted part re-
mains unpeeled.
Certain shapes cannot be
peeled by the blade.
Increase the peeling
thicknes, and slow the spin
speed to leave less peel.
It is possible that part of the
blade is particularly worn.
Replace the peeler blade
with a new one.
Sometimes the skin
fails to be peeled.
Is the skin already in contact
with the blade before starting?
Adjust the starting angle
and spin speed to reduce
fouling.
Has it been some time since
you used the peeler? Has
juice hardened on (in) it?
Use a damp cloth to carefully
wipe clean the peeler blade.
Have you inserted the item far
off center?
Affixing an item to a prong
requires practice.
Peeling stops in mid-oper-
ation.
The peeler seems
to be catching on
something
In some cases the peeler will
hit a hard spot, or a thick peel
(i.e. on citrons) which it can-
not remove.
Adjust the start angle,
peeling thickness and spin
speed to improve peeling.
There is a chance that fruit
juice has entered the unit
during a peeling operation.
If cleaning does not correct
the issue, notify the Compa-
ny.
An item separates from
the prong.
--
It is possible that the selection
of the pin does not match the
item to be peeled.
Choose the prong that
matches the size of the
item.
Are you peeling a very large
item, or a very soft item?
Reducing the spin speed
may help, but there is a
limit.
Have you attempted to af-
fix the item once again, or
peeled it more than once?
Inserting an item twice
increases prong damage
as well as increasing the
, and the chance the item
will weaken and slip off the
prong.
An item wobbles on the
prong.
--
Have you inserted the item off
center?
Some wobble is OK, assum-
ing that the item is peeled
correctly.
Skin scatters in small piec-
es.
--
Some hard items, such as
onions and potatoes
, are peeled in thinner pieces.
This is normal.