9
6. Correct Use of the FAP-1001
1) Pre-operation preparation
● In order to prevent a possible electric shock please connect a ground fault interrupter to this unit.
● Install the unit in a well-lit area free of clutter or obstacles.
● When using an extension cord, confirm that the cord is undamaged. Use a 1500W rated extension
cord. The cord should be as short as possible.
● Fasten the main unit to the installation base.
● Set "Receiving container" for the peeled item discharge position and skin drop position.
● Plug the power cord into the inlet of the main unit and plug the cord plug into the power outlet. Make sure
that the power switch is not turned ON.
2) Pre-operation inspection
● Check to see that the fixing prong is properly attached. (
See page 15
)
Caution!
If the prong is not properly fitted to the unit, there is a danger
that it will come into contact with the peeler blade, damaging
both of these parts.
• Check that the fixing prong is free of damage. If it is bent, or makes a rattling noise, it must be re-
paired or replaced.
● Check the state of the spring. Replacement is necessary when it is fractured. (
See page 14
)
Caution!
When a fractured spring is used:
● The arm and the fixing prong may come into contact with
each other and cause damage.
● The arm may fall and be damaged.
• Check that the peeling blade is free of damage. If the blade is dented or bent, it must be replaced.
(
See page 14
)
• Check to see that the arm is correctly attached. If it is not, the peeler will not function properly.
(
See page 13
)
Caution!
If the arm is not attached correctly, it may contact the fixing
prong, causing damage to these parts.
Содержание FAP-1001