![Astoria 1GR Скачать руководство пользователя страница 46](http://html.mh-extra.com/html/astoria/1gr/1gr_use-and-maintenance-manual-instructions-for-the-user_2990321046.webp)
USER manual
46
of
216
POWER SWITCH
• Open the water mains valve.
•
Turn the power switch to position “1” (elec-
tricity is supplied to the pump to automati-
cally fill up the appliance's heating unit and
steam heating unit) and wait for the heating
unit to be automatically filled with water.
•
Turn the main switch to position “2” (full electricity is sup-
plied, including to the heating element in the heating
unit) and wait for the machine to warm up completely.
6.3.2
Electric heating (versions with
Display)
• Press the machine's main switch (1).
1
• Wait for the heating unit to be automatically filled with
water, if necessary.
•
Wait another second or so for the automatic test to be
carried out.
WAIT
FUNCTIONAL TEST
TEST RESULTS
- OK -
•
The machine is ready for use when the following mes-
sages appear on the display:
1.0 BAR
120°C
09:16 09-10-12 5
1.0 BAR
120°C P
09:16 09-10-12 5
Time
Heating unit
pressure
Date
Day of the week
Heating unit
temperature
Programming
indicator
See the days of the week reference table in para-
graph "Programming a Working Day" on page 54.
1
2
0
If the temperature inside the heating unit is lower
than 90°C (machine’s heating-up phase), the mes-
sage LOW will appear on the display.
To restart the machine, press and hold the same buttons for
3 seconds.
6.3.3
Gas heating (if a gas system
has been installed)
•
Turn the power switch (
A
) to position 1.
• Open the gas valve (
B
) on the mains.
•
Press and hold the button (
C
) and simultaneously press
the ON button (
D
). Once the flame has ignited, hold down
the knob (
C)
for a few seconds, to allow the thermocouple
to activate correctly.
• Then check that the flame has ignited through the win
-
dow (
E
).
•
Wait for the operating pressure shown on the pressure
gauge to reach the working value of 0.1-0.12 MPa (1-1.2
bar).
A
D
C
B
E
6.3.4
El gas heating (if a gas
system has been installed)
During the machine's heating-up phase (roughly
20 minutes), the negative pressure valve will re-
lease steam for a few seconds until the valve closes.
Do not open the gas mains when the heating unit is empty.
•
Proceed as indicated in the previous paragraph.
• After checking that the flame has ignited, turn the power
switch (
A
) to position 2. In this way the heating unit's
heating element is powered and the operating pressure
will be reached more quickly.
•
Wait for the operating pressure shown on the pressure
gauge to reach the working value of 0.1-0.12 MPa (1-1.2
bar).
6.3.5
Turning off the machine
Turn off the machine using the main switch or power switch.