IOTRON
TM
Trademark of ASTI
IOTRON
TM
pH / ORP / ISE / DO / Conductivity Measurement Products Lines
INSTALLATION GUIDE
The software in the three (3) channel touchscreen controller is specifically designed to be used with IOTRON™ &
ZEUS™ series smart digital RS-485 MODBUS RTU HiQDT pH, ORP & D.O. sensors. All functionality detailed in this
manual can also be performed by the ASTI supplied handheld battery powered communicator
(excluding only changing
of the baudrate and node address which is only possible using the Windows software)
. The Windows software can
perform ALL possible operations on the smart digital RS-485 MODBUS RTU HiQDT pH, ORP & D.O. sensors. The ASTI
supplied HiQDT HMI+PLC touchscreen controller package that is a turn-key unit available for purchase ready for plug
and play commissioning with a robust software suite (see this manuals for details on all capabilities and usage details).
Alternatively any PLC of your choice can be programmed to accomplish the same features if you prefer. If implementing
on your own PLC instead of using the ASTI supplied package the software layout can serve as a roadmap for your own
installation if you wish. All functions performed by this software can also be accomplished on your own customer
supplied PLC with the appropriate modbus function calls (see separate implementation guide for details) with the
exception of setting the baudrate and node address (Windows software must be used to perform these tasks). Please see
the separate installation guide for the HiQDT pH, ORP & D.O. sensors for use with customer supplied PLC if you plan to
choose this route for commissioning of your system where you will supply all of the software on the PLC to be used.
The software contains the following
menus
and
fields
, all of which are accessible starting with the main menu.
MENUS
(Left Column in the Main Menu):
Page(s)
MENUS
(Right Column in the Main Menu):
Page(s)
“Select Channel” menu
•
Set the working channel (global setting)
•
Note about baudrate & node address
8
8
“Hold Channel Output” menu
•
Set channel on hold for maintenance
26
“Sensor Type” menu
•
Sensor Type
•
Node Address Scheme for HiQDT Sensors
9
9
“Analog Output Status” menus
•
Configure Analog Output
•
Scale Analog Outputs
•
Wiring for Analog Outputs
27
28
29
“Calibrate Sensor” menu
•
Display Current Calibrations
•
Autobuffer Calibration (pH Only)
o
Auto pH Buffer A.P. Cal (Offset)
o
Auto pH Buffer Acid Slope Cal
o
Auto pH Buffer Base Slope Cal
•
Manual Calibration
o
Manual ORP Offset Cal
o
Manual pH A.P. (Offset) Cal
o
Manual Temperature Offset Cal
o
Manual Calibrate pH Acid Slope
o
Manual Calibrate pH Alkaline Slope
•
Dissolved Oxygen (D.O.) Calibrations
•
Adjust Dampener Settings
•
Reset All Calibrations
10
10
11
11
12
12
12
13
14
15
15-16
17
18-19
20
20
“Set Output & Relays” menus
•
Enter low & high setpoints for PROCESS
setpoints & view status of process relays
•
Enter low & high setpoints for TEMP
setpoints & view status of temp relays
•
Wiring for Relay Outputs
“MODBUS TCP Slave Regsiters” menus
•
HiQDT Sensors PROCESS VALUES
•
HiQDT Sensors CALIBRATION INFO
•
HiQDT Sensors ANALYTIC INFO
30
30
31
32
33
34
“Controller Info & Sensor Diagnostics” menu
•
Snapshot of the current sensor analytic info
21
“Relay Event Status” menu
•
Shows record of relay On/Off events
35
“Email Notifications” menus
•
Email Notifications Setup
•
Email Notifications Menu
22
23
“Remote Access 2.0” menu
•
Initial Setup of remote access feature
•
Remote client login to controller
36
37
“Controller Info” and “Trend Display” menu
•
Display information about current controller
•
Hard Reset back to factory defaults
•
View trending graphs for each channel
24
24
25
Miscellaneous
Download, view logged data (local/remote)
Sample Process, Calibration & Analytic Data
Appendix “A, B, C, D, E & F”
Software License Agreement (EULA)
38-40
41-43
44-49
50-51