(BESA-12V24G) User Manual
Version GS 17628
11
Version GS 17628
EFB
tests Start/Stop or Enhanced Flooded Batteries.
GEL
tests Gel Cell VRLA Batteries with units of measurement in Cold Cranking Amps.
7. Before selecting the ratings ‘CCA, SAE, EN, IEC, DIN, CA and JIS #’ from the menu, check the battery
specification value. This value can be checked on the battery labels as some of the examples shown
below:
8.
Once the selection has been done, it will proceed to the display as shown below (Fig.24):
9. If the rating is selected under JIS # (Japanese Industrial Standard) then you need to refer to the
conversion chart provided separately with the Tester when purchased to convert to CCA ratings.
Refer to the battery model (example: 80D26L or NX110-5L) on the Cold Cranking Amps (CCA), WET is
580 CCA and AGM is 630 CCA.
10.
You can also use the rough CCA guide below, basing on the engine capacity of vehicle but the
percentage (%) Life is not that precise as compare to the actual battery rating due to this rough estimation.
1000 – 1299 cc
300 CCA
1300 – 1599 cc
400 CCA
1600 – 1999 cc
500 CCA
2000 – 2999 cc
700 CCA
3000 – 3500 cc
800 CCA
Fig.24