9.
PRODUCT DISCONNECTION
9.1
MAINS DISCONNECTION
To completely disconnect the system from the mains follow the steps below:
•
If the product is connected to a non-switched fused spur, remove the fuse from the spur.
•
If the product is wired to a plug and connected to a power outlet, disconnect the plug from the power outlet.
•
In the case of a battery being fitted there are two power sources to disconnect before any service or
maintenance work is carried out.
NOTE:
To safely power down and prevent the risk of data loss the system must be switched off as described
in the ‘
’ section. Only disconnect directly from the mains in an emergency.
9.2
BATTERY DISCONNECTION
The battery is connected to the Traka Touch PCB located on the back of the control panel.
For Battery disconnection, carefully disconnect the connector from the Traka Touch PCB.
WARNING:
Never disconnect the wires from the green connector whilst the cable is still connected to the
battery terminals.