October 11, 2011
Page 16 of 22
66 3081 018-4
4.4 Events
All operations of the safe are logged in the safe memory and sent as events to VISIONLINE.
Below is a list of the events available in VISIONLINE:
Event
Description
Auto Relock Error
The Auto Relock attempt was unsuccessful.
Clear Memory
Deletes the audit trail.
Cold Start
The microprocessor of the safe was restarted. It happens when safe looses power
and gets it back again. Cold start does not delete anything from the safe memory.
Configuration Changed
The safe configuration was changed.
Decoded
The safe has been decoded.
Door Time-out
The locking bolt/latch hit the frame during locking. After 2-3 seconds it
automatically retracted.
Five Incorrect Codes
The user has entered five different incorrect codes, which sets the safe in
countdown or service mode.
Incorrect Guest Code
An incorrect code has been entered by the user. The incorrect code is recorded and
shown in the safe log.
Incorrect Service Code
An incorrect service code has been entered.
Locked
Safe locking by user code, card, or fingerprint depending on safe model.
Logoff
A logoff with a service unit has taken place. The User ID will be the same as for
‘logon’ (see above).
Logon
A logon with a service unit has taken place. The concerned user ID is stored in the
safe memory.
Low Battery
Mechanically Opened
The locking latch was moved mechanically without the safe running the motor.
New Date/Time
Internal safe clock was changed; this was the new date and time.
Old Date/Time
Internal safe clock was changed; this was the old date and time.
‘Ser’ in display
The safe is unoperational and in “service mode”. Technical staff must service open
the safe.
Service Code Changed
Service code of the safe has been changed.
Service Countdown
Five incorrect service codes have been entered, which sets the safe in countdown
or service mode.
Service Opened
The safe has been successfully service opened.
Service Open Error
Service opening failed because the safe did not manage to move the locking
bolt/latch to open position.
Tamper Activated
The tamper switch has been activated.
Time-out
The safe was not locked within 3 seconds after the code was entered or the
card/fingerprint was swept.
Unlocked
Normal unlocking of the safe by code, card, or fingerprint depending on
safe model.
Содержание Sentinel Digital Ph III RF-Online