65
Assembly
EN
No. Description
No. Description
1
Door drive unit/release
: Make
28
Jumper JP3: Factory setting item 1
Item 2. 120 Ω on RS485 X16 with terminating resistor if data bus faults
occur
2
Fault
:
Control unit: Open contact
29
Jumper setting JP4: Factory setting item 1
Item 2. 120 Ω on RS485 X16 with terminating resistor if data bus faults
occur
3
Door contact
: Contact setting depending on lock (trip latch) and input
X13
30
Finger scanner
:
(RS 485 BUS)
4
Cylinder contact
: Contact switches when cylinder is actuated
31
MOD BUS
: WAGO node (RS 485 BUS)
5
Bolt contact
: Contact switches immediately with mFlipLock bolt
32
Output supply
: as well as X15 without S1
6
Door handle contact
: Door handle contact left switches immediately
33
Fuse and LED
: Function (separate operating instructions for AWS, pages
8 and 12)
7
External handle coupled
: Door handle contact opposite to escape
direction switches when coupled and with e-access handle status
displayed on the right
34
Supply
: 11–27 V DC +/- 10%
8
Outputs
35
BMZ
: Fire alarm input. Fire control system
LED status outputs
9
LED status inputs
36
Evaluation control system (AWS) V1.1
10
Inputs
37
Door drive unit = TA
11
Factory settings
: Terminals 16 and 15 bridged
38
LED status outputs
12
External door contact (Reed)
: Monitoring contact (open)
manufacturer´s recommendation (bolt protection function)
39
Fault
13
External timer day/night/Office function
: mFlipLock/FlipLock perma-
nent door release
without
activation TA(X1), flip latch released.
40
Door
14
Locked
: All inputs are inactive. mFlipLock locked.
41
Jumper setting item 1
:
1 jumper in the middle. 24 DC/AC must be
present on terminals 38 and 39 for operation. (Triggered on loss of
voltage)
Jumper setting item 2
: 2 jumpers one above the other. Terminals 38
and 39 must be bridged for operation. If the BMZ is triggered, then
these bridges must be separated by the BMZ (
factory setting
)
15
Motorised unlocking:
Unlocked/flip latch released. Input only active
when Day mode or DAY TA(X1) has 1.5-s impulse
42
Cylinder
16
External timer day/night/Day mode
: Couple door handle in opposite
direction to escape direction.
43
Bolt
17
Impulse button
: Bolt will be retracted by 70%, flip latch blocked.
44
Door handle in escape direction (e-access door handle left)
18
Access control
(reader): Impulse present = coupling in time. Door
handle coupled in opposite direction to escape direction
45
Door handle opposite to escape direction (e-access door handle right)
19
Impulse button/Unlock impulse
: Unlocked, flip latch released. Impulse
and permanent release. TA(X1) controlled as long as Impulse input is active.
46
Door contact
20
Access control
(reader): If DIP 5 ON and DIP 6
OFF, then TA(X1) 1.5 s
47
Office function
21
External timer for day/night/Impulse and timer
: e.g. by introducing a
TA(X1) 1.5-s impulse DIP 5 ON /6 OFF
48
Locked
22
Key switch
: e.g. door drive unit Fresh Air/Office function DIP 5/6 OFF
49
Radar
23
DIP 2 OFF = operating current (closed when deenergised)
DIP 2 ON = closed-circuit current (open when deenergised)
50
Day mode
24
Reserve
51
Impulse
25
6-pin connection cable LIYY 2x2x0.22 + 2x0.5 MSL item 10/20 m
14471403/04
52
GND
26
DIP switch functions (separate operating instructions AWS, page 8)
53
LED mode: Flashes when faults occur
27
Service button
: Function (separate operating instructions for AWS,
page 14)
54
Connection for mFlipLock
Содержание MSL 25574PE-SV
Страница 19: ...19 Montage DE Abb 6 Sachschaden vermeiden 1 2 1 2 max 150 N ...
Страница 23: ...23 Montage DE Schloss manuell prüfen Abb 9 Manuelle Funktionsprüfung 1 2 3 4 5 ...
Страница 55: ...55 Assembly EN Fig 6 Prevent material damage 1 2 1 2 max 150 N ...
Страница 59: ...59 Assembly EN Checking the lock manually Fig 9 Manual function testing 1 2 3 4 5 ...
Страница 91: ...91 Montage FR Fig 6 Éviter les dommages matériels 1 2 1 2 max 150 N ...
Страница 95: ...95 Montage FR Contrôle manuel de la serrure Fig 9 Contrôle fonctionnel manuel 1 2 3 4 5 ...
Страница 127: ...127 Montaggio IT Fig 6 Evitare danni materiali 1 2 1 2 max 150 N ...
Страница 131: ...131 Montaggio IT Verificare manualmente la serratura Fig 9 Verifica di funzionamento manuale 1 2 3 4 5 ...
Страница 146: ...146 IT Problema causa soluzione ...