Problem
Cause
Solution
The door can be pushed
or pulled open by hand
although it should be
locked.
The bolt is not extended when the door is closed.
Adjust the door and the position of the strike plate
so that the latch engages freely in the strike plate
and door frame and can position itself.
The bolt is not extended when the door is closed.
Locking cylinder jammed.
Check and replace the locking cylinder if necessary.
Check switchover operation using a key.
The bolt jumps back out
of the lock immediately
after opening the door.
Door handle cannot be pushed down far enough.
Rebate gap is set too wide.
Check and, if necessary, correct the rebate gap.