background image

3

Installation Instructions

SE LP10 9600 Series Exit Device 

With MELR

Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All 

rights reserved. Reproduction in whole or in part without the express written 

permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.

1) Regulatory Compliance

Changes or modifications to this unit not expressly approved by the party responsible 
for compliance could void the user’s authority to operate the equipment.

FCC

:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These 

limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and 

can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio 

communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful 

interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the 

interference by one or more of the following measures:

• 

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• 

Consult the dealer or an experienced radio/TV technician for help.

Industry Canada:

This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the 

following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including 

interference that may cause undesired operation. 

Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. 

L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter 

n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and 

operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with 

any other antenna or transmitter.

Cet équipement est conforme aux limites d’exposition aux radiations de la FCC définies pour un environnement non contrôlé. Cet équipement doit 

être installé et utilisé à une distance minimale de 20 cm entre le radiateur et votre corps. Cet émetteur ne doit pas être co-localisé ou fonctionner en 

conjonction avec une autre antenne ou un autre émetteur.

Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for 

the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the 

equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.

Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal 

(ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres 

utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité 

nécessaire à l’établissement d’une communication satisfaisante.

2) Warning

To avoid possible damage from electrostatic discharge (ESD), some basic precautions should be used when handling electronic components:
• 

 Minimize build-up of static by touching and/or maintaining contact with unpainted metal surfaces such as door hinges, latches, and  

          mounting plates especially when mounting electronic components such as readers and controllers onto the door.
• 

Leave components (reader and controller) protected in their respective anti-static bags until ready for installation

• 

Do not touch pins, leads or solder connections on the circuit boards

This product can expose you to lead which is known to the state of California to cause cancer and birth defects or other reproductive harm.  

For more information go to: 

www.P65warnings.ca.gov

.

Ce produit peut vous exposer au plomb qui, dans l’état de la Californie, est reconnu pour causer le cancer, des anomalies congénitales ou 

d’autres problèmes de reproduction.
Pour plus d’informations, visitez: 

www.P65warnings.ca.gov

.

Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and Corbin Russwin makes 

no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing fire 

rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority Having 

Jurisdiction) to ensure compliance with all applicable codes and ratings.

!

Содержание Corbin Russwin SE LP10 9600 Series

Страница 1: ...nment can cause premature wear and a lessening of security For Technical Assistance call Corbin Russwin at 1 800 810 WIRE 9473 Attention Installer Installation Instructions SE LP10 9600 Series Exit De...

Страница 2: ...ut the express written permission of ASSA ABLOY Access and Egress Hardware Group Inc is prohibited Table of Contents 1 Regulatory Compliance 3 2 Warning 3 3 General Description 4 4 Specifications Feat...

Страница 3: ...her antenna or transmitter Cet quipement est conforme aux limites d exposition aux radiations de la FCC d finies pour un environnement non contr l Cet quipement doit tre install et utilis une distance...

Страница 4: ...multiple credential formats 3 General Description 4 Specifications Features The reader requires 12VDC for power while the lock accepts 24VDC DPS Door Position Switch McKinney Electronic Transfer Hing...

Страница 5: ...IPS B03 Reader Harness Assembly 200 bit Wiegand output 763F669 FIPS B04 Reader Harness Assembly 75 bit Wiegand output 763F629 IPS B03 Reader Harness Assembly Standard Indicator Configuration 784F869 I...

Страница 6: ...Standard Indicator Configuration 1 763F649 FIPS B03 Reader Harness Assembly 200 bit Wiegand output 763F669 FIPS B04 Reader Harness Assembly 75 bit Wiegand output 763F629 IPS B03 Reader Harness Assemb...

Страница 7: ...g a FIPS 201 PIV credential causes LED to turn amber as credential is authenticated Reader emits a short beep when credential is successfully read Reference Diagram 1 PIN 4 Tan DPS COM PIN 2 Gray Lock...

Страница 8: ...NO Fail Secure Operation DPS DPS QC12 Electric Hinge From McKinney Panel Circuitry Unsupervised Open Collector Tamper 5VDC A to D Converter 1K 1K 1K Input Connection Input Connection IMPORTANT Pin 7...

Страница 9: ...wn 7 GREEN_LED Yellow 8 LOCK NEG Violet 9 LOCK POS Gray 10 DPS NC Pink 11 DPS COM Tan 12 12VDC DATA 1 DATA 0 RX NO RX COM Electrical Access Control Panel By Others Use NC for Fail Safe Operation Lock...

Страница 10: ...eak Average Peak Reader 100mA 220mA n a n a MELR n a n a 250mA dogged 1A inrush 600mA during retraction UL294 S319 BHMA A156 25 currently not applicable to TAMPER or Alternate Indicator option 8F 4F 8...

Страница 11: ...Reader 8F 4F Not used 3287 Door Position Switch DPS RX COM Blue 6 EARTH GROUND Brown 7 GREEN_LED Yellow 8 DATA 1 DATA 0 RX NO RX COM Electrical Access Control Panel By Others Use NC for Fail Safe Ope...

Страница 12: ...for size of exit device function and hand 2 Prep door according to supplied door markers Outside FM382 for Rim SVR CVR FM386 for Mortise Inside FM387 Left Hand Reverse LHR Outside Inside Right Hand Re...

Страница 13: ...plate and gasket using two 2 8 18 x 5 8 Phillips flat head self drilling screws Fig 3b 3 For non fire rated interior doors no fire shield or gasket is required simply install backplate using two 2 8 1...

Страница 14: ...und the reader Ensure access hole in the bezel aligns with screw hole on reader The reader should be mounted so holes face bottom of door Fig 4b 2 Align top of reader with top of backplate Pivot the r...

Страница 15: ...Fig 5a for Mortise skip to Step 6 b If required modify by cutting cylinder tailpiece Correct length is 1 16 to 3 16 2 to 5mm beyond cylinder housing cam c Assemble cylinder 1 Insert cylinder housing p...

Страница 16: ...s Hardware Group Inc is prohibited 7 Installation Instructions Continued Install mortise lock following FM168 instructions but do not install armored front at this time a Feed lock wire through wire h...

Страница 17: ...reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group Inc is prohibited Fig 6c d Tighten down set screw to prevent cylinder m...

Страница 18: ...Trim Assembly Rim CVR SVR a Make sure tailpiece is oriented vertically b Feed trim wire harness through wire harness hole Fig 7 c Mount trim assembly to door pulling slack wire towards device side of...

Страница 19: ...hibited 7 Installation Instructions Continued 8 Install Exit Device Follow instructions packed with device to secure device to door 9 Install Head Cover a Lay wire device harnesses across hole Fig 9a...

Страница 20: ...Fig 10a a Feed reader harness through mounting plate Fig 10a b b For Rim CVR and Mortise Begin to secure mounting plate to inside door surface by fastening 2 Phillips flat head machine screws to lower...

Страница 21: ...pin connector on reader harness Fig 11a b 11 Connector Attachments Fig 11b Fig 11c Fig 11a c Connect ElectroLynx 4 and 8 pin connectors from the door harness to black 4 and 8 pin connectors of the re...

Страница 22: ...ws no fire plate required 7 Installation Instructions Continued a NOTE For fire rated doors only Secure mounting plate and fire plate using 2 8 1 1 4 Phillips pan head self drilling screws provided Fi...

Страница 23: ...a Feed excess ElectroLynx wire harness back into door b Feed excess trim and exit device harnesses under head cover c Install inside escutcheon using 2 8 32 x 5 8 oval head screws Fig 13a Note Be care...

Страница 24: ...ration and Operational Check Not Used Do not install the end cap until electrical operation is verified in order to confirm LED signaling Do not discard the end cap and hardware Configuration Check a...

Страница 25: ...tated turn lever and check that latch retracts c Check that push bar fully retracts the latch d Close door Ensure latch fully extends into strike and does not bind Note For fail safe trim cylinder wil...

Страница 26: ...he test unit checks for proper wiring card reader data integrity lock functionality including lock unlock door position status and request to exit REX status In addition this tool provides product dem...

Страница 27: ...ies Exit Device With MELR Copyright 2020 ASSA ABLOY Access and Egress Hardware Group Inc All rights reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY Acces...

Страница 28: ...and Edge are trademarks or registered trademarks of HID Global in the U S and or other countries All other trademarks service marks and product or service names are trademarks or registered trademarks...