22
Installation Instructions
SE LP10 9600 Series Exit Device
With MELR
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All
rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Fig. 12a
Fig. 12b Detail
12. Install Mounting Plate and (optional) Fire plate:
Ground
wire
FIre Plate
Mounting
Screws
For non-fire rated door, use #8-5/8” Phillips pan
head screws (no fire plate required).
7) Installation Instructions (Continued)
a. NOTE: For fire-rated doors only.
Secure mounting plate and fire plate using (2) #8 1-1/4”
Phillips pan head self-drilling screws provided (Fig. 12a). Ensure wires from reader are properly
routed under flap of fire plate.
b. Secure mounting plate using (2) remaining Phillips flat head self-drilling screws provided. Ensure
wires from reader are properly routed under flap of fire plate.
c. Place ground wire eyelet between upper right mounting plate hole and screw when securing
mounting plate (and fire plate if used) to door (Fig. 12a, b).
Configuration for SVR
Fig. 12c
Configuration for Rim/CVR/Mortise
Ground
wire