10
Installation Instructions
SE LP10 9600 Series Exit Device
With MELR
Copyright © 2020, ASSA ABLOY Access and Egress Hardware Group, Inc. All
rights reserved. Reproduction in whole or in part without the express written
permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
Product
8 PIN CONNECTOR
4 PIN CONNECTOR
1-Black
2-Red
3-White
4-Green
5-Orange
6-Blue
7-Brown
8-Yellow
1-Violet
2-Gray
3-Pink
4-Tan
ACCESS CONTROL DEVICES: SE LP10 Mortise, ElectroLynx wire Color / Function assignments
SE LP10
MELR
12VDC
(Reader)
WIEGAND
WIEGAND
RX
RX
EGND
TAMPER
12/24 VDC
(LOCK RELAY)
DPS
DPS
GREEN_LED*
NEG
POS
DATA_1
DATA_0
NO
COM
EGND
OPEN
COLLECTOR
NEG
POS
NC
COM
INPUT
Wiring in accordance with the NEC, ANSI/NFPA 70
Fail secure installations are subject to approval of local AHJ
Fail secure installations shall permit use of Listed panic
hardware to allow emergancy exit from the protected area.
Failure to follow proper ESD safe grounding procedures could
lead to equipment failure.
SE LP10 (MELR) Application Diagram #3 (12/24VDC System)
12V
24V
Average
Peak
Average
Peak
Reader
100mA
220mA
n/a
n/a
MELR
n/a
n/a
250mA
dogged
1A inrush
600mA
during
retraction
*UL294, S319, & BHMA A156.25 currently not applicable to TAMPER or Alternate Indicator option
8F
4F
8M
4F
8F
4F
4M
8M
8M
4M
4M
4M
8M
8M
SELP10
Reader
8F
4F
Not used
Door
Position Switch (DPS)
When door is closed, the
DPS is electrically closed
RX (COM) - Blue, 6
**EARTH GROUND - Brown, 7
*TAMPER - Yellow, 8
(-)
12VDC
(+)
Electrical
Access
Control
Panel
(By Others)
Use (NC) for
Fail Safe
Operation
Lock
Relay
(NO) Fail
Secure
Operation
DPS
DPS
Panel Circuitry
Unsupervised
Open Collector
Tamper
5VDC
A to D
Converter
1K
Ω
1K
Ω
1K
Ω
Input
Connection (+)
Input
Connection (
-
)
Power Supply
(By Others)
12-24VDC
H N G
120 VAC
Input
Black (Hot)
White (Neutral)
Gr
een (Gnd)
12VDC
- +
- +
8F
4F
8M
4M
†NOTE: All Door Cables, Frame
Cable and QC12 Hinge are
specified & ordered seperately
Wiring shown is inside door frame
MELR Exit
Device
Not
used
Not
used
Not
used
8-pin to 4-pin
3 “ Adaptor
Harness
Required
Supplied
Not
used
†Male to Male
Adaptor Door Cable
12 Conductor
(3” length typically)
†Door Cable - 12 conductor
(length selected by door width)
†
QC12
Hinge
READER NEG - Black, 1
READER POS - Red, 2
DATA 1 - White, 3
DATA 0 - Green, 4
RX (NO) - Orange, 5
MELR NEG - Violet, 1
MELR POS - Gray, 2
Not Used - Pink, 3
EGND - Tan, 4
EGND
6) Wiring Diagrams (Continued)