SPRING AND DOOR OPEN POSITION
8. The RED LED flashes 4 times per second, when tension is near the selected
class.
- When the door closer shaft stops rotating (takes about .80s) mount the ann
(Door must be in dosed position).
9. Then press S -button.
- The RED LED lights up. The operator is ready to set the door closed position.
10. Set the door closed position by rotating the pulse disk to door closing direction.
When the RED LED turns off, the door closed position is set.
k
"
ecc?J
11. Turn power OFF and check how the door closes without motor. If the spring does
not close the door properly, the tension must be set again. (Control Point 14:
Factory reset).
16