EXTERNAL CONNECTIONS

Sequencing (pages 25-26)

Safely sensor (page 27)

Impulse Inslde (page 28)

Impulse outside (page 28)

Locking circuit (page 29)

NO

Lock control relay

C

NC

GND

+ 12VDC

GND

+

24

vec

@

i

I

l_ .....•..

5equendng

jumpers

~

.

••

.

.

led-unit

X4

~

Note!

Max. output 12 V

DCI

0.5 A or 24 V DC

I

0.8 A

Lock control relay

Contacts ratings: Max power 0,8A130V resistive.

O,3A130Vinductive

The total resistance of the control switch and its wiring must not exceed 100 ohm,

when the switch is closed.

24

Содержание ABLOY DA401

Страница 1: ...ABLOY DA401 DA402 Swing door operator _ PROGRAM VERSION 1 53 AbloyOy An ABBA ABlOY Group company...

Страница 2: ...cates the edge of the notch the door operator stops the door PULSE COUNTER The counter has three sensors Two count the pulses and the disk direction the other senses the perimeter of the disk PULSE CO...

Страница 3: ...ram selector e g 0 MANUAL 1 AUTO or 2 OPEN The right hand display section indicates the status of opening pulses the safety sensor and the locking circuit Program selector status Error Adjustment OK s...

Страница 4: ...until the bolt is in Ifthere is no lock check the jumper in connector 10 and 11 Impulse outside active Operator opens the door and close it after preset delay o If no impulse is given check connectio...

Страница 5: ...on When the desired control point has been selected with the 5 button pressing the A button validates the control value and flashes on the display The Adjustment LED will also flash except for a seale...

Страница 6: ...er second if the tension of the spring is not set 5 Turn the program selector away form MANUAL position and back in three seconds 6 Now the operator tensions the spring After it takes about 20s operat...

Страница 7: ...en press S button The RED LED lights up The operator is ready to set the door closed position 10 Set the door closed position by rotating the pulse disk to door closing direction When the RED LED turn...

Страница 8: ...impulse Hold open time 8 8 1 10 Operator sensitivity Sealed 7 9 1 5 Closing speed 5 10 1 3 Closing direction Final speed 3 11 0 10 Lock up force Sealed 0 12 1 8 Safety feature sensitivity Sealed 5 13...

Страница 9: ...e the smooth 1 10 function of safety feature 1 lowest force Operator sensitivity Sealed 8J The acceleration of the door affects to smoothness of the operator or how sharp the door reacts to e g wind p...

Страница 10: ...ion 1 lowest speed 1 3 HOLD OPEN TIMES 9 Delav time for inside impulse g Delay 0 15 seconds When the erator receives the opening impulse the lock is release immediately but the door is delayed in open...

Страница 11: ...pening stepwise opening Used in two doors following each other The first door opens from impulse and commands the second door to open The opening delay of the second door is adjusted In control point...

Страница 12: ...toring fadory settings Sealed o Operator on 0fcening side f fixed value 1 Operator on c osing side Ixed value 2 Restore factory settings reset door closed position 3 Sprin tension value 2 0 3 Note set...

Страница 13: ...23456789 o 950640 Fire adapter blue Mains s leh blacJc bl Ground AUTO MANUAL OPEN TBOOmA Pulse counter l 27 26 black 250 bIad 240 whI 23 22 do 21 200 19 __ _ _ _ 1 l J 5elecllhe rtght supply voltage w...

Страница 14: ...29 NO Lock control relay C NC GND 12VDC GND 24 vec i I l_ 5equendng jumpers led unit X4 Note Max output 12 V DCI 0 5 A or 24 V DC I 0 8 A Lock control relay Contacts ratings Max power 0 8A130V resist...

Страница 15: ...etectors are used a 950640 Fire adapter AUTO MANUAL OPEN The jumper is ON The jumper Is OFF red black JUMPERS Fire detector input If the jumper is on the adapter requires N O output from the fire dete...

Отзывы: