DOOR FORCES
CONTROL POINTS
D[]
0 ...10
8[]
0... 10
,
-
.
-,
-
Lock-up force (Sealed)
The operator keeps the door closed at preset force for
1 second following which this reduced to half of the preset
value. Value 0 ~ no lock-up force, 10 highest.
Pressure closed before opening
The operator drives the door against the closed position
for a preset value of 1 second. Value 0 ~ no force, 10
highest.
SEQUENCING
8GJ
0...3
MASTER
1
or
0
lOCK CONTROL
Sequencing (Sealed)
1
= Opening and dosing sequencing for pair of rebated doors
The master door opens first and then the slave.
The slave door closes first and then master door.
All impulses are connected to the master.
2 = Sequential opening (stepwise opening)
Used in two doors following each other. The first door opens
from impulse and commands the second door to open.
The opening delay of the second door is adjusted In control
point
4.
Note! The inside impulse connection is not operational.
3
=
Inte~ock controlled doors
Used in two door following each other. The first door opens
from impulse and the second door opens from impulse after
the first door is fully dosed.
The bolt Information is needed In connectors 10 and 11.
Master (Sealed)
Master operator for double doors
o ~ No operation/slave
operator
1 = Master operator
1
or
0
1...10
~
<9~
Operation of lock control relay
O~ no operation for lock relay in MANUAL-mode
1~ lock control relay activates when receiving an impulse
in MANUAL-mode
lock control relay hold time
Fire doors - adjust the lock control relay hold time to a
minimum.
20