26
TEST PROGRAM AND FAULT INDICATIONS
TEST PROGRAM AND FAULT
INDICATIONS
TEST PROGRAM
The machine must be in its starting state (obtai-
ned by pressing the main power button).
Connect the jumper on the outputs ST4-1 and
ST4-2.
Start
Start the test program.
P1
TDC44: Start the condensation water
pump.
P2
or wait for 60 seconds and the test pro-
gram will continue.
The program heats, increasing the temperature
by 14° in max. 10 minutes, then allows it to cool
for 5 minutes (testing that the heating element is
working).
The value detected by the humidity sensor can
vary according to the environment and on
whether there is wet clothing in the tumble drier.
INTERNAL COUNTER
The electronic control unit contains an internal
counter of the number of drying cycles.
To show the number of drying cycles in the
display:
1. Switch off the power switch,
and connect
the jumper on the outputs ST4-1 and ST4-2.
2. Switch on the machine again.
3. Press the
P8
-button five times.
The counter is shown on the display.
The counter disappear when the jumper is dis-
connected.
Temperature
measured by
thermistor
Amplified voltage
value from humidity
sensor
FAULT INDICATIONS
Overfill:
Overfill condensation
water holder.
Maximum running time: Maximum running
time achieved, 3 hours.
Thermistor fault:
Thermistor fault.
Sensor fault:
Fault in humidity
sensor.
Reasons for faults
Open or short circuit in thermistor
Program stops and display shows "Thermistor
fault". The thermistor may have become discon-
nected or have an internal fault. A serviceable ther-
mistor has a resistance of between 60 and 40 k
W
at 20-30°C.
Thermistor not installed in fan housing
The heating element will remain switched in for
as long as the thermistor cannot detect the selec-
ted air temperature. This can lead to an excessive-
ly high air temperature in the drum.
Blocked filter
The overheating protection (150°C) will be trip-
ped and the machine will stop. Reset is manual in
the back of the machine.
Humidity sensor not installed in fan housing
or control unit
The machine will stop after 20 minutes.
Incoming phase missing
• Error L1, the machine will stop after 20
minutes. Low heating element power (720 or
600W).
• Error L2, the machine will not start. Indica-
tion lamp not lit.
• Error L3, the machine operates but the run
ning time is too long (low heating element
power (1900W)).
380V between each phase and neutral
The fan motor stops after a few seconds. Over-
heating protection trips, heating element and con-
trol damaged.
Содержание TDC33
Страница 1: ...PROFESSIONAL TUMBLE DRYER 5kg SERVICE MANUAL 8064375 Publication date Sep 2002...
Страница 2: ......
Страница 6: ...TABLE OF CONTENTS 4...
Страница 85: ......
Страница 86: ......