background image

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

• 

Do not try to light any appliance.

• 

Do not touch any electrical switch; do not use any phone in your building.

• 

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

• 

If you cannot reach your gas supplier, call the fire department.

• 

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or 

mobile home, where not prohibited by local codes. 

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible 

for use with other gases, unless a certified kit is used.

853277C-4103i

Warning: If the information in this manual is not followed exactly, a fire or explosion may result causing property  

damage, personal injury or loss of life.

INSTALLER: Leave this manual with the appliance. 

CONSUMER: Retain this manual for future reference.

MODELS: DVAG11 / DVAG17 / DVAG30

CALIFORNIA PROPOSITION 65 WARNING:

This product can expose you to chemicals including carbon monoxide, which 

is known to the State of California to cause cancer, birth defects and/or other 

reproductive harm. For more information, go to www.P65warnings.ca.gov

Ce produit peut vous exposer à des agents chimiques, y compris au monoxyde de 

carbone, lesquels sont reconnus dans l’État de la Californie comme causant le cancer et 

des malformations congénitales ou autres dommages au fœtus. Pour obtenir plus de 

renseignements, veuillez consulter le site www.P65warnings.ca.gov

United States Stove Company

PO Box 151, 227 Industrial Park Rd.,

South Pittsburg, TN 37380

PH: (800) 750-2723

www.usstove.com

Содержание DVAG11

Страница 1: ...pliance is not convertible for use with other gases unless a certified kit is used 853277C 4103i Warning If the information in this manual is not followed exactly a fire or explosion may result causin...

Страница 2: ...th the exhaust vent terminal for the horizontally vented gas fueled heating the appliance or equipment The sign shall read in print no less the one half inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR...

Страница 3: ...nstaller service agency or the gas supplier Model No Input Power Btu Hr kW Max Gas Inlet Pressure inch W C mm W C Min Gas Inlet Pressure inch W C mm W C Pres Reg Settings Manifold inch W C mm W C Valv...

Страница 4: ...odes CHECK GAS TYPE Use only the type of gas indicated on the rating plate Model DVAG11 Model DVAG30 Model DVAG17 17 36 441 mm 20 508 mm 6 61 168 mm 20 508 mm 27 36 695 mm 6 61 168 mm 26 30 668 mm 32...

Страница 5: ...operating the appliance A manufactured home USA only or mobile home OEM installation must conform with the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 or when such stand...

Страница 6: ...N WALL Remove the required heat shield from the box and fold it as indicated in this illustration fold along the perforated lines and break off when installing in a 2 X 4 wall Align the holes on the h...

Страница 7: ...ustible materials is one 1 inch 25 4 mm Vent terminal must be 18 0 away from an adjacent wall Minimum clearance between vent cap and combustible material 1 3 4 IMPORTANT The appliance s venting system...

Страница 8: ...inwater 8 Before attaching the vent cap to the exterior wall run a bead of non hardening mastic silicone caulk around its outside edge so as to make a seal between it and the plate see figure 15 9 Pla...

Страница 9: ...g should be accessible for test gauge connections upstream of the gas supply connection to the heater Pressure Nat Gas 7 W C to 10 5 W C Nat Gas 178 mm W C to 267 mm W C L P Gas 11 W C to 14 W C L P G...

Страница 10: ...t smell gas go to the next step 6 Find pilot The pilot can be seen through the view port on the top of the appliance 7 Turn gas control knob counterclockwise to PILOT Keep control knob depressed and c...

Страница 11: ...ERMOCOUPLE PILOT FLAME Correct pilot burner flame pattern Figure 23 Correct main burner flame pattern top view Models DVAG11 SECONDARY FLAME PRIMARY FLAME THERMOCOUPLE PILOT FLAME Figure 25 Correct ma...

Страница 12: ...Thermocouple connection looses at control valve Hand tighten until snug then tighten turn more Pilot flame not touching thermocouple which allows couple to cool causing pilot flame to go out This pro...

Страница 13: ...mber and replacement part s number When calling the authorized distributor have ready model number of your heater the replacement part number WARNING Turn off heater and let cool before servicing Veri...

Страница 14: ...41 DVAG11 DVAG17 DVAG30 Outdoor Mounting Plate 893045 DVAG11 893046 DVAG17 DVAG30 Burner 81311 DVAG11 81312 DVAG17 81313 DVAG30 Vent Cap 893047 DVAG11 893048 DVAG17 893049 DVAG30 Piezo Ignitor 80808 D...

Страница 15: ...07 Date _____________________ Engineer Name ________________________________ License No ____________________________________ Company _____________________________________ Telephone No _______________...

Страница 16: ...16 Notes...

Страница 17: ...r des fins de r f rence Lorsque vous nous crivez veuillez indiquer le num ro complet du mod le qui figure sur la plaque signal tique de l appareil de chauffage Lorsque vous commandez des pi ces de rec...

Страница 18: ...____________________________ Service de 07 Date _____________________ Nom de l ing nieur ____________________________ N de licence _________________________________ Compagnie _________________________...

Страница 19: ...11 DVAG17 DVAG30 Plaque de montage d ext rieur 893045 DVAG11 893046 DVAG17 DVAG30 Br leur 81311 DVAG11 81312 DVAG17 81313 DVAG30 Amorceur Pi zo 80808 DVAG11 DVAG17 DVAG30 R gulateur 81307 GN 81308 GPL...

Страница 20: ...remplacez le R gulateur de gaz d fectueux Replacez le r gulateur de gaz Flamme jaune lors de la combustion du br leur L entr e tuyau est bloqu e Retirez le blocage Mauvaise connexion des tuyaux Conne...

Страница 21: ...el ch Le bouton de commande ne peut pas tre enfonc au complet Enfoncez le bouton de commande compl tement Le bouton de commande n a pas t press assez longtemps D s que la veilleuse s allume gardez le...

Страница 22: ...la veilleuse du br leur Figure 23 Configuration correcte de la flamme principale du br leur vue en plong e Models DVAG11 FLAMME SECONDAIRE FLAMME PRIMAIRE THERMOCOUPLE FLAMME DE LA VEILLEUSE Figure 25...

Страница 23: ...z Si vous d celez une odeur de gaz ARR TEZ Suivez B dans les informations de s curit se trouvant au dessus de cette tiquette Si vous ne sentez rien passez l tape suivante Tournez le bouton de commande...

Страница 24: ...en gaz et le radiateur Pression Gaz nat Entre 7 po et 10 5 po de colonne d eau Gaz nat Entre 178 mm et 267 mm de colonne d eau Gaz de p trole liqu fi Entre 11 po et 14 po de colonne d eau Gaz de p tr...

Страница 25: ...r ext rieur passez un cordon de mastic non durcissant mastic silicone autour de son bord ext rieur de mani re sceller herm tiquement le plat et la plaque voir figure 15 9 Placez le capuchon et vissez...

Страница 26: ...es mat riaux combustibles est de 25 4 mm 1 po La sortie d vacuation doit se trouver 457 2 mm 18 po d un mur adjacent L espace de d gagement minimal entre le couvercle de ventilation et les mat riaux c...

Страница 27: ...ixez les l aide des 6 vis t le 1 En tenant compte des d gagements minimaux mentionn s dans le tableau 2 localisez le montant du mur le plus proche qui servira tenir l appareil et marquez le centre du...

Страница 28: ...terrasse ou d un balcon 91 cm 3 pi au dessus dans un rayon de 3 m 10 pi horizontal Espace de d gagement conform ment aux codes d installation locaux et aux exigences du fournisseur de gaz Important Ce...

Страница 29: ...e gaz indiqu sur la plaque signal tique Mod le DVAG11 Mod le DVAG30 Mod le DVAG17 441 mm 17 36 po 508 mm 20 po 168 mm 6 61 po 508 mm 20 po 695 mm 27 36 po 168 mm 6 61 po 668 mm 26 30 po 820 mm 32 28 p...

Страница 30: ...t l entretien doivent tre effectu s par un installateur qualifi un service d entretien ou le fournisseur de gaz Num ro de mod le Puissance d entr e BTU heure kW Max Pression de l entr e de gaz po W C...

Страница 31: ...de chauffage au gaz vacuation horizontale La plaque signal tique doit indiquer en caract res imprim s d au moins un 1 2 pouce 13 mm de haut GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS VACUA...

Страница 32: ...rovenant du march secondaire et install e de mani re permanente Cet appareil n est compatible qu avec le type de gaz indiqu sur la plaque signal tique Cet appareil n est pas compatible avec d autres t...

Отзывы: