INSTALLATION
IMPROPER INSTALLATION
The use of other components other than stated
herein could cause bodily harm, heater damage,
and void your warranty. The manufacturer will not
be held responsible for damage caused by the
malfunction of a stove due to improper venting or
installation.
FLOOR PROTECTION
This heater must have a non-combustible floor
protector (UL1618 ember protection) installed
beneath it if the floor is of combustible material.
US:
The floor pad or non-combustible surface
should be large enough to cover at least the area
under the product and 6” (152 mm) beyond the
front and beyond each side of the fuel loading
and ash removal openings. Floor protection must
extend under and 2” (51 mm) to each side of the
chimney tee for an interior vertical installation.
Canada:
Require a minimum of 450 mm [17.7”]
beyond the front of the unit and 200 mm [7.8”]
beyond each side of the unit. A Floor Protector of
1/4” thick is recommended for this installation.
FLOOR PROTECTOR
A
C
C
B
A Rear
1”
25 mm
B Front
6”
152
mm
C Side
6”
152
mm
CLEARANCES
Your pellet stove has been tested and listed
for installation in residential, mobile home in
accordance with the clearances given below. For
safety reasons, please adhere to the installation
clearances and restrictions. Any reduction in
clearance to combustibles may only be done by
means approved by a regulatory authority.
D Backwall to unit
8”
203 mm
E
Sidewall to flue
12-1/2”
317 mm
F
Sidewall to top edge of
unit
8”
203 mm
G Backwall to Flue
2”
50 mm
H
Adjacent wall to unit
3”
76 mm
J
Alcove depth
36”
914 mm
K
Alcove height
60”
1524 mm
E
D
G
F
E
F
BACK WALL
SIDE
W
ALL
BACK WALL
SIDE
W
ALL
H
H
H
H
J
K