Miscellaneous (Continued)
Screw Quantity Monitoring Sensor (Optional)
As an optional attachment, there is a sensor which monitors the quantity of screws
remaining in the hopper. With this attachment connected to the signal line, you can set
the sensor to monitor the level of screws remaining in the hopper.
Attachment Procedure
• Remove the main body cover.
• Using the accompanying bolts, attach the sensor to the top lid. (2 holes)
• Put the harness through the notch at the back of lid.
• Put the external output signal line which is attached to the sensor into the
connector at the top of the board. Put the signal line out through the line-out
hole in the cover at the rear.
•
FUNCTION:
Screw empty: signal high (ON)
• Incoming current: shall be limited to less than 100mA
•
CAUTION:
Additional resistor is required on external circuit for regulating
current**
•
CAPACITY:
Max DC current: 100mA
• External supply voltage: 5 - 24VDC (Max: 27VDC)
•
NOTE:
Please keep the length of output signal wire less than 3m
• The Blue wire functions as signal output high (Collector end), with the green wire
as common (Emitter end)
• When installing the main body cover, take care not to catch or pinch the harness.
• Next, adjust the screw quantity monitoring sensor by following the instructions in
the sensor manual.
• Details on how to adjust and use the sensor are in the sensor operating manual.