![ASG OM Series Скачать руководство пользователя страница 21](http://html.mh-extra.com/html/asg/om-series/om-series_manual_2981860021.webp)
ASG, Division of Jergens, Inc.
15700
S. Waterloo Road | Cleveland, OH 44110-3898 | Phone: (888) 486-6163 | Fax: (216) 481-4519 | Email: [email protected] | Web: www.asg-jergens.com
21
Part Adjustments and Replacement (Continued)
Replacing the Passing Plate
Turn OFF the power switch before starting replacement and adjustment.
• Use the passing plate, rail and escape that correspond with the diameter of the
screws to be used.
• Remove the passing plate. Do not lose the attached bolts. Using bolts other than
those supplied with this machine may result in a malfunction.
• Refer to Check and Adjust the Passing Plate for adjustment.
Replacing and Adjusting the Brush
Turn OFF the power switch before starting replacement and adjustment.
• If the brush is too worn to sweep screws off of the rail, replace it.
• Turn ON and OFF the power switch in order to set the brush bristles facing to the
left and detach the brush assembly.
• The brush assembly can be disassembled as shown in the figure on the right.
• After reassembling, check that the front part of the brush doesn’t come in contact
with the passing plate. The ideal clearance is 0mm.
• For adjustment, refer to Adjusting the Brush Height on page 10.
!
!