and gently wipe chamber area.
* actual filter and UV lamp replacement periods may vary based on the environment in which the
unit is used. More contaminated environments will shorten filter life. Check filters regularly to
ensure optimal operation of the unit
9. Disassembly
9.1. Front cover removal:
Using the included front panel removal tool, insert the tool into the top side air intake slot and
push towards the back of the unit until the front panel springs free. Repeat process for opposite
side and then pull the whole cover upwards to take to remove it and expose the filter
compartment; see steps 1, 2 &3 below.
9.2. Prefilter removal:
After removing the front cover, turn the swivel tabs located in the 4 corners to release the prefilter;
see illustration ’A’ below.
9.3. HEPA/Carbon filter removal:
After removing the Prefilter grasp the small pull tabs located on the top of the HEPA/Carbon filter
and pull hard towards you. You may have to pull several times to release the filter as it has a
special air-tight seal on the back edges which may provide resistance during removal; see
illustration ‘B’ below.
9.4. Ultraviolet Germicidal Lamp removal:
Grasp lamp gently by end caps and rotate the clockwise or anticlockwise until the bulb is loose in
the socket. Pull the bulb straight out towards you. DO NOT twist the bulb or put excessive
force on the glass or end caps as this may cause the bulb to break; see illustration ‘C’ below.