![ASEA AC36V-1 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/asea/ac36v-1/ac36v-1_operation-manual_2981676045.webp)
AC36V-1, -3 / AC45V-1, -3 / AC54V-1, -3 Operations Manual....
45
TRANSFER ON OVERLOAD CONTROL
Feature: Disabled, Select Genset: 1
Enable Disable Forward Back Exit
7.3
LOAD MANAGEMENT OPERATION
, cont.
7.3.5 Automatic Transfer to Generator
, Single or Master Converters (Seamless Transfer
installed)
Upon Shore Alarm, the Automatic Transfer to Generator feature may be used to perform a Seamless
Transfer to a pre-selected generator. This implies connection and setting of the Generator Autostart
Control feature (needed to signal a generator to start and hold the set warm-up time before
transferring). The transfer is not initiated until Voltage Droop has occurred as the load savings
afforded may have taken the converter out of Shore Cord Alarm.
From the front panel, press the
SHORE POWER
+
F2
buttons, and then Transfer (
F3
) to access the
following screen:
Press the
F1
or
F2
buttons to adjust the Feature or Select Genset settings; Forward (
F3
) to advance
the cursor to the Select Genset setting; Back (
F4
) to return the cursor to the Feature setting, and Exit
(
F5
) to save the settings and exit the screen. When the cursor is on the Feature setting, the
F1
/
F2
buttons will read Enable/Disable. When the cursor is on the Select Genset setting, the
F1
/
F2
buttons
will read More/Less.
Default Range
Feature DISABLED
DISABLED/ENABLED
Genset
1
-
4
Содержание AC36V-1
Страница 15: ...AC36V 1 3 AC45V 1 3 AC54V 1 3 Operations Manual 15 5 1 MECHANICAL INSTALLATION cont FIGURE 2 MECHANICAL OUTLINE...
Страница 16: ...AC36V 1 3 AC45V 1 3 AC54V 1 3 Operations Manual 16 5 1 MECHANICAL INSTALLATION cont FIGURE 3 CONTROLS...
Страница 34: ...AC36V 1 3 AC45V 1 3 AC54V 1 3 Operations Manual 34 6 5 REMOTE COMMUNICATIONS cont FIGURE 7 RS 232C PINOUT...
Страница 56: ...AC36V 1 3 AC45V 1 3 AC54V 1 3 Operations Manual 56 8 DIAGNOSTICS cont FIGURE 8 STATUS WORD BIT DEFINITIONS...