Ascon Tecnologic - e34B - OPERATING INSTRUCTIONS - PAG. 8

a contact that is NO in normal operation then closed  
during the alarm (see alarm memory);

-t

 

To control a silenceable alarm device through a con-
tact that is NC in normal operation then opened during 
the alarm;

-L

 

Control an alarm that cannot be silenced through a 
contact that is NC in normal operation  then opened 
during the alarm;

-n

 

To control an alarm with a memory function through 
a contact that is NC in normal operation then opened 
during the alarm;

on

 

To command a device that must be turned ON when 
the instrument is ON.  The output is therefore deac-
tivated when the instrument is not powered or is in 
standby mode.  This mode of operation can be used 
as a control of the shop window lighting, anti-fogging 
resistors or other utilities;

HE

 

To control a heating device in neutral zone (

rHC

 = 

nr

);

L1

 

Showcase light connected to 

Normal

/

Eco

 mode.  The 

output turns ON when the 

Normal

 mode is active while it 

is turned OFF when the 

Eco

 mode is active;

L2

 

Internal cell light.  The output is always OFF and only 
switches ON from a digital input  signal when it is con-
figured as door opening switch (

iFi

 = 

1

2

3

);

oF

 

Output disabled.

If one of the outputs is configured as auxiliary output (= 

Au

), 

its function is set by parameter 

oFo

 and its operation can be 

conditioned by the time set at parameter 

otu

.

oFo

 parameter can be configured for the following functions:

oF

 

Auxiliary output not active;

1

 

Temperature control output delayed with NO con-
tact: the auxiliary output is activated with a delay that 
can be set with parameter 

otu

 applied to the output 

configured as 

ot

.  The output is then turned OFF at 

the same time as the 

ot

 output is disabled.  This func-

tion mode can be used as a command for a second 
compressor or for all other working utilities according 
to the same ot output conditions, but which must be 
delayed after the start up of the compressor to avoid 
excess electricity absorption;

2

 

Activation by digital input.  The output is activated by 
a  digital input signal if correctly configured (

iFi

 = 

9

). 

These commands have a bi-stable (toggle) function (at 
first pression the output is activated, at the second is 
disabled).  The 

Aux

 output can be turned OFF auto-

matically after the time set at parameter 

otu

.

When 

otu

 = 

oF

 the output is activated and deactivated only 

manually, via the digital input.  Differently, the output, once 
activated, is turned OFF automatically after the 

otu

 time.  

This mode of operation can be used as a control of the shop 
window lighting, anti-fogging resistors or other utilities.
If present, the internal buzzer can be configured by param-
eter 

obu

 for the following functions:

oF

 

Buzzer always disabled;

1

 

The Buzzer sounds when an alarm is active;

2

 

The Buzzer sounds when a key pressed (no alarm);

3, 4

  The Buzzer sounds both when a key pressed and 

when an alarm is active.

5.6 

Temperature control

The instrument controls the temperature with an 

ON

/

OFF

 

action and operates on the outputs configured as ot and 

HE

 depending on the 

PR1

 probe measuring, the acive Set 

Point/s 

SP1

 (or 

SP2

SP3

SPE

 and 

SPH

), the Hysteresis 

rd

 

(or 

rEd

 and/or 

rHd

) and the function mode set with 

rHC

.  

Using 

rHC

 can be set the following functioning modes:

C

 

Cooling

 

H

 

Heating

SP

Temp.

rd

time

off

off

SP

rd

time

ON

rHC

 = 

C

rHC

 = 

H

off

off

ON

ON

ON

ON

ON

Output

ot

Output

ot

Pr1

Temp.

Pr1

Depending on the function mode programmed with parameter 

rHC

 the differential is automatically considered by the control-

ler with positive values for a 

Refrigeration

 control (

rHC

 = 

C

or negative values for a 

Heating

 control (

rHC

 = 

H

).

nr

 

Neutral Zone

SP

off

off

ON

Temp.

time

rd
rd

off

off

rHC

 = nr

ON

ON

HE

ot

Outputs

Pr1 

When 

rHC

 = 

nr

, the output configured as 

ot

 operates with a 

cooling action (like 

rHC

 = 

C

) while the output configured as 

HE

 operates with a heating action both with the Active Set 

Point (

SP1

SP2

SP3

SPE

 or 

SPH

).  The intervention differ-

ential (

rd

/

rEd

/

rHd

) is automatically assumed by the control-

ler to have positive values for the cooling action and negative 
values for the heating action.

HC

 

Cooling and Heating with independent Set Points

SP

SPH

off

off

off

Temp.

time

rd

rd

off

off

off

RHC

 = HC

ON

ON

ON

ON

ON

HE

ot

Pr1 

Outputs

As in the previous case, when 

rHC

 = 

HC

 the output configured 

as 

ot

 operates with cooling action (like 

rHC

 = 

C

) while the out-

put configured as 

HE

 operates with heating action (

rHC

 = 

H

).  

In this case, however, the Set Point for the 

ot

 output is the 

active one between 

SP

SPE

 or 

SPH

, while for the 

HE

 output 

the Set Point is 

SPH

.  The intervention differential for the 

ot

 

output is the active between 

rd

rEd

 or 

rHd

 and is automati-

cally assumed by the controller to have positive values for the 
cooling action while for the output 

HE

 the differential is 

RHd

 

considered with negative values as for the Heating actions.
In this mode, the activation of the 

Turbo

 cycle causes the 

instrument to operate with Neutral Zone and 

SPH

 set point.

C3

 

Cooling with three automatic modes

  

The instrument operates in cooling mode only, but this 
selection activates automatic switching between the 
three 

Normal

/

Eco

/

Turbo

 modes (described at para-

graph “

Operating modes

”).

Содержание e34B

Страница 1: ...g the compressor electric heating or hot gas cycle inversion The controller is equipped with special defrost optimization functions and with other functions that can be used to obtain energy savings f...

Страница 2: ...el of the parameters Pressed together with the key for 5 s allows the keyboard unlock 5 LED dp Stand by During the normal operation is the decimal point when the instrument is placed in Stand by mode...

Страница 3: ...d is correct the instrument displays the code of the first parameter and it will be possible to program the in strument in the same way described in the previous section The password protection can be...

Страница 4: ...yable variable and its value So with the keys keys you can view all the variables pr1 Probe Pr1 temperature measurement Pr2 Probe Pr3 temperature measurement Pr3 Probe Pr3 temperature measurement Lt M...

Страница 5: ...nt con nection inside housing it is not equipped with either switches or internal devices to protect against current overloads the installation will include an overload protection and a two phase circ...

Страница 6: ...ng Elapsed the itt time after the door has been closed and from the activation of SPE Setpoint Eco mode by iEt parameter Eco Normal switching To use this function it is necessary to set the Digital In...

Страница 7: ...delayed for the time programmed with parameter iti The iFi parameter can be configured for the following functions 0 Digital input not active 1 Cell door opening with NO contact at input closure and...

Страница 8: ...ration can be used as a control of the shop window lighting anti fogging resistors or other utilities If present the internal buzzer can be configured by param eter obu for the following functions oF...

Страница 9: ...tions are disabled if the relative parameters are set to OFF oF 5 8 Defrost control The defrost control acts on the outputs configured as ot dF ad dH The type of defrost is set by the parameter ddt EL...

Страница 10: ...y occur with normal op eration when to ensure more system efficiency the defrost ing interval is programmed with a time that is often too short With the parameter ddd Defrost interval percentage reduc...

Страница 11: ...fine the display behaviour during defrost on The ddL parameter locks the display at the last Pr1 temperature reading during all the defrost cycle until at the end of defrost the temperature has not re...

Страница 12: ...l the alarm memory signal press any key It must be remembered that if an output function is desired with an alarm memory oo1 oo2 oo3 oo4 An n it is necessary to set the parameter AtA on 5 10 1 Tempera...

Страница 13: ...g 200 V off off off ON ON HU LU AL 10 V 10 V Volt time V 5 11 Function of keys and The key function can be defined using the tUF param eter to perform the following functions oF The key carries out no...

Страница 14: ...perature measured by the Pr1 probe using a 2 digit display Power supply TVR Y cable length 10 m max For more information see the user manual for the TVR Y device 6 4 RS485 Serial Interface with ARS1 D...

Страница 15: ...en Door with Fan Fn and Output ot Lock 4 External Alarm 5 External alarm with control output disabling 6 Normal Eco select 7 On Stand by select 8 Start a Turbo cycle 2 15 iti Digital Input Delay oF Di...

Страница 16: ...42 dEE Lengh of defrost cycle for evaporator probe error oF Function disabled 1 59 s 1 99 min 10 43 Ftn Fan time activation with ot output compressor OFF oF Function disabled 1 59 s 1 99 min 5 44 FtF...

Страница 17: ...tput function oF Function disabled 1 Control output ot delayed 2 Manual activation by key oF 69 otu Time relative to auxiliary output oF Function disabled 1 59 s 1 99 min oF 70 tUF Key Function oF No...

Страница 18: ...ust be shipped to Ascon Tecnologic with a detailed description of the faults found without any fees or charge for Ascon Tecnologic except in the event of alternative agreements 10 TECHNICAL DATA 10 1...

Страница 19: ...ERING CODE MODEL e34B Instrument with mechanical keyboard e34NB Instrument with NFC technology and mechanical keyboard a POWER SUPPLY H 100 240 VAC F 12 VAC VDC b OUTPUT 1 OUT 1 R Relay SPST NO 16A AC...

Страница 20: ...Ascon Tecnologic e34B OPERATING INSTRUCTIONS PAG 20...

Отзывы: