1222AHS OPERATORS MANUAL – LIGHT KIT ASSEMBLY
17
LIGHT KIT ASSEMBLY
Figure 9 - Light Kit Assembly
G
ENERAL
I
NFORMATION
This implement warning light kit is used on towed
implements when the implement obscures the warning
lamps on the towing vehicle.
The kit will also meet the lighting requirements for over
12 feet wide or that extend over 6 feet beyond the
centerline of the towing vehicle.
The lamps will operate as turn signals when used in
conjunction with a tractor equipped with turn signals.
This kit includes two warning lamps, tow tail lamps, 7-
pin plug, and mounting hardware. The plug has
additional capacity for work lights.
A
SSEMBLY
NOTE:
All item numbers refer to Figure 9.
1.
Attach the defoliator to tractor.
CAUTION: MAKE SURE PTO IS
DISENGAGED, TRACTOR IS SHUT OFF
AND THE KEY IS IN YOUR POCKET
BEFORE WORKING ON THE DEFOLIATOR.
2.
Assemble one amber warning lamp (#2) to the
outer frame using lock washer (#8) and bolt (#7)
on lamp. Repeat for the other warning lamp.
IMPORTANT:
The implement warning light kit is being
used to satisfy width lighting requirements. The amber
lamps must be located within 40.6cm (16 inches) of the
lateral extremities of the defoliator and must flash in
unison with the towing vehicle warning lights.
Locate warning lamps on implement as follows:
•
Equal distance as possible from implement
centerline.
•
As far to the rear as possible.
•
Visible from front and rear.
•
At least 61cm (24 inches) from base of lamp to
ground.
B
RACKET
I
NSTALLATION
NOTE:
Red tail lamps MUST be symmetrical about
centerline and 2 to 5 feet from center of machine
respectively.
1.
After warning lamps are located, locate angle
brackets (#13, part #476490) on frame.
2.
Secure brackets with 3/8 inch U-bolts (#16), lock
washers (#14), and nuts (#15).
3.