AXP1440 Shelf Description
60
AXP1440 Installation and Use (6806800H23T
)
2.8
Fan Tray Modules (FTMs)
The AXP1440 supports two fan trays in a push/pull configuration. Each fan tray contains six
dual counter rotating fans. The lower fan tray is accessible from the front of the chassis and
contains the replaceable air filter. The upper fan tray is located in the rear of the chassis.
The FTM has a ejector handle which signals the IPM Sentry software for hot swap. If your
system is not running high-availability software, behavior of the LED may be indeterminate.
The face plate of the upper and lower FTMs has the following indicators:
Table 2-7.
FTM LED Status Indicators
FTM LED
LED Color
State/Condition
In-Service (IS)
Green
Off: no service
Blink: FTM activating
Glow Steady: service available
Out-of-Service (OOS) and Failure
Red (default)
Off: service available
Blink: Deactivation requested
Glow Steady: no service
Hot Swap (H/S)
Blue
Off: FTM is not ready to be removed
Blink: Deactivation requested
Glow Steady: FTM is ready to remove
Figure 2-5. Lower Fan Tray Module, Front View
LEDs
Содержание AXP1440
Страница 1: ...AXP1440 Installation and Use P N 6806800H23U October 2018...
Страница 8: ...6 AXP1440 Installation and Use 6806800H23U Contents...
Страница 10: ...List of Figures 8 AXP1440 Installation and Use 6806800H23U...
Страница 12: ...List of Tables 10 AXP1440 Installation and Use 6806800H23U...
Страница 20: ...AXP1440 Installation and Use 6806800H23U About this Manual 18 About this Manual...
Страница 79: ...Site Preparation AXP1440 Installation and Use 6806800H23U 77 Figure 3 4 Planning Checklist 2...
Страница 80: ...Site Preparation 78 AXP1440 Installation and Use 6806800H23U...
Страница 108: ...AXP1440 Shelf Installation 106 AXP1440 Installation and Use 6806800H23U...
Страница 152: ...Shelf Management Alarm Module 150 AXP1440 Installation and Use 6806800H23U...
Страница 155: ...1...