AXP1440 Shelf Description
58
AXP1440 Installation and Use (6806800H23T
)
2.6.5
Zone Locations on a Blade
The backplane provides dual star Base Interface and dual star Fabric Interface connections at
each slot with segmented power (four power segments) provided by the dual PEMs.
Zone 1 provides the system management and power interfaces, such as redundant
-48VDC power and IPMB
Zone 2, the data transport interface, provides the Base and Fabric interfaces, and
Update Channels through the ZD connectors per front-side blade
Zone 3 provides the direct interconnect for user designated I/O
NOTICE
Rear Transition Modules connect directly with the connectors on the front-side blade
and do not make the connection through the backplane.