
FRU Installation
110
AXP1440 Installation and Use (6806800H23U
)
Procedure - No Installed Front Blade
The following procedure describes the installation of the RTM without a front blade installed.
1. Locate the slot the RTM is to be installed into the shelf's rear which must be the same
as that of the front blade.
2. Ensure that the top and the bottom handles of the RTM are in an outward position by
squeezing the lever and the latch together.
3. Insert the RTM into the shelf by placing the top and bottom edges in the card guides
of the slot.
4. Slide the RTM into the slot.
5. Apply equal and steady pressure to the RTM to carefully slide the RTM into the shelf
until you feel resistance. Continue to gently push the RTM until the RTM connectors
engage.
6. Squeeze the lever and the latch together and hook the lower and the upper handle
into the shelf rail recesses.
Содержание AXP1440
Страница 1: ...AXP1440 Installation and Use P N 6806800H23U October 2018...
Страница 8: ...6 AXP1440 Installation and Use 6806800H23U Contents...
Страница 10: ...List of Figures 8 AXP1440 Installation and Use 6806800H23U...
Страница 12: ...List of Tables 10 AXP1440 Installation and Use 6806800H23U...
Страница 20: ...AXP1440 Installation and Use 6806800H23U About this Manual 18 About this Manual...
Страница 79: ...Site Preparation AXP1440 Installation and Use 6806800H23U 77 Figure 3 4 Planning Checklist 2...
Страница 80: ...Site Preparation 78 AXP1440 Installation and Use 6806800H23U...
Страница 108: ...AXP1440 Shelf Installation 106 AXP1440 Installation and Use 6806800H23U...
Страница 152: ...Shelf Management Alarm Module 150 AXP1440 Installation and Use 6806800H23U...
Страница 155: ...1...