TECHNICAL SPECIFICATIONS
UNITS
NEAT 70
NEAT 80
NEAT 90
*Total heat output
Kcal/h
5160
6020
7310
kW
6
7
8.5
Recommended hourly consumption of firewood
Kg/h
1.8
2
2.4
Efficiency
%
80
80
80
Exhausts temperature
°C
247
247
259
CO emissions
(by providing O
2
at 13%)
%
0.090
0.090
0.090
Yield range
(minimum - maximum)
kW
3.4 - 8.5
3.4 - 9.2
3.4 - 10.5
Fuel
-
Wood, Briquette
Device dimensions (W x D x H)
cm
68.5/45/48
78.5/45/48
88.5/45/48
Combustion chamber dimensions (W x D x H)
cm
50x34x23
55/34/23
60/34/23
Flue draft
Pa
12(±2)
Heated area
m
2
25 - 90
25 - 120
25 - 140
Weight
kg
105
112
118
External air inlet.
The section must be increased by 20% for each additional
meter after 1 m
cm
Ø 10
Smoke outlet diameter
cm
Ø 15
**Minimum flue height
m
4
Minimum heating area
m
2
25
* The fireplace operates with intermittent combustion technology. In this case intermittent combustion means the normal use of the fireplace, e.g. new
firewood is added as soon as the previous are burned, forming a sufficient amount of cinder.
** The internal section of the flue must be increased by 10% per 500m altitude above sea level.
Table 14.1