I
NSTALLATION
&
U
SERS
M
ANUAL
FIREPLACE
| NEAT 70/80/90
13 |
Page
17.
Place the spring by screwing the jam nut and the hexagon socket screw.
(Pic. 7.2.19)
18.
Ensure that the washer is in on the hinge.
Place the door and and clip the
retaining ring.
(Pic. 7.2.20)
Before installing a NEAT fireplace you must close the inner part of the flue with a deflector with an
appropriately drilled plate or other refractory material that can withstand high temperatures
without damage.
The space extending around and over the device up to the deflector must be ventilated
continuously. For this reason you must allow cool air from a lower spot, for example, the bottom and
the outlet of the hot air from above.
(Pic. 7.2.21)
These openings must remain free and not able to be covered. The must also have a minimum
surface of 300cm
2
, for example, a grille with size 30x10cm.
This way you achieve:
greater security
Increase on the heat of the room, due to the air circulating around the device.
The hot air extract grille must be placed on top of the trunk approximately 20cm from the ceiling.
The grille must always be installed, as its purpose is to allow, the heat that builds up inside the trunk
to be released in the room and also to relieve the pressure created.
7.3.
Installation on a ARTE base
ARTE® gives you the option to install NEAT fireplace on a compatible base
(Pic. 7.3.1) (optional equipment). In
this case you can align the device by leveling the ARTE base legs. So the disassembly of the main unit from the
metallic shell is not necessary.
Pic. 7.2.16
Pic. 7.2.17
Pic. 7.2.18
Pic. 7.2.19
Pic. 7.2.20
Pic. 7.2.21
Pic. 7.3.1