background image

5

Multifunction LCD Digital Timer

Nomenclature                                                                         

                     

                    

                 

                

                 

                 

                 

                

                 

         Reset Indicator 

         Control Output Indicator

     Present Value (character height: 9 mm)

     Time Unit Display (If the time range is 0 min, 

     0.0 min, 0 h, 0.0 h, 0h0 min, this display flashes 

     to indicate timing operation)

     Set Value (character height: 4 mm)

     The First Setting Key 

     The Second Setting Key

     The Third Setting Key 

     The Fourth Setting Key 

     The Fifth Setting Key

     The Sixth Setting Key

     Reset Key (resets present value and output)

     Mode Key (changes modes and setting items)

     Key Protection Indicator (the preset value is 

     OFF)     

     Set Value (Range) A, B Display

Содержание TC-Pro480 Series

Страница 1: ...Ver 3 0...

Страница 2: ...fe terminals screw terminal block models Three language instruction manual Applied to connect PC and HMI Contents Model Number Structure 2 Speci cations 3 Nomenclature 5 Connection 6 Operating Procedu...

Страница 3: ...onnector 1 5m Cable CAB 090A485 9 pin Female D sub cable for RS 422 connector 1 5m Cable CAB 090A422 9 pin male D sub adapter for CAB 090A232 CAB 090A485 CAB 090A422 ADP 090401 9 pin Female D sub cabl...

Страница 4: ...ate Minimum input signal width 1 or 20 ms selectable same settingfor all inputs Power reset Minimum power opening time 0 5 s except for A 3 b 1 and F mode Reset system Power reset execpt for A 3 b 1an...

Страница 5: ...ns min 5 A at 250 VAC resistance load EMC EMI Emission Enclosure Emission AC mains EMS Immunity ESD Immunity RF interference Immunity Conducted Disturbance Immunity Burst Immunity Surge Immunity volta...

Страница 6: ...0h0 min this display flashes to indicate timing operation Set Value character height 4 mm The First Setting Key The Second Setting Key The Third Setting Key The Fourth Setting Key The Fifth Setting K...

Страница 7: ...trol output OUT Outputs take place according to designated operating mode when timer reaches corresponding set value I O Functions 2 Stage Timer Inputs Start signal Starts timing Reset Resets present...

Страница 8: ...hanged to timer twin timer 2 stage timer selection mode the present value is reset and output turns OFF See note 3s min See note 3s min Timer setting mode See Run Mode on page 10 Twin Timer setting mo...

Страница 9: ...nication on off Set the transmision speed with key Set the parity check with key Set the date bit with key Set the stop bit with key Set the Station address HEX with key Set communication on off with...

Страница 10: ...tection level KP1 to KP 5 The key protection indicator is lit while the key protection switch is set to ON See note 3s min See note 3s min K P ON Setting mode K P OFF Setting mode Run Mode K P Setting...

Страница 11: ...de Output time Input signal width NPN PNP input mode K P level Set the time range with key Set the time mode with key Set the output mode with key Set the input signal width with key Set the NPN PNP i...

Страница 12: ...e present value is displayed in the main display and the ON duty ratio is displayed in the sub display A and Range light at the same time Set the ON duty ratio used in ON OFF duty adjustable flicker m...

Страница 13: ...put mode is set to A A 1 A 2 A 3 b or b 1 If the output time is set to 0000 00s hold is displayed and the output is held Input signal width iflt Set the minimum signal input width 20ms or 1ms for sign...

Страница 14: ...e Twin timer function setting mode KP 1 KP 2 KP 3 KP 4 KP 5 NPN input PNP input 20ms 1ms flicker OFF start flicker ON start Elapsed time Remaining time Set the K P level with key Set the NPN PNP input...

Страница 15: ...999999h ON Time range timr Set the range to be timed in the range 000 000s to 999999h Timer Mode timm Set either the elapsed time UP or remaining time DOWN mode ON OFF Start Mode totm Set either the...

Страница 16: ...e with key Forecast value Absolute value Set time range with key For details refer to time range list Set the output mode with key A F 1 Set the input signal width with key 20ms 1ms Set the NPN PNP in...

Страница 17: ...t value Present value Forecast set value Set set value with the corresponding keys Set forecast set value with the corresponding keys When the absolute value is selected Present value Set value 1 Pres...

Страница 18: ...nt setting error by prohibiting the use of certain operation keys by specifying K P level KP 1 toKP 5 For details refer to Key Protection Setting Mode on page 8 Forecast Value Setting Example F 1 Mode...

Страница 19: ...en the power comes ON or when the reset input goes OFF The control output is controlled using a sustained or one shot time period Timing Power Start signal input Output Basic Operation Output is insta...

Страница 20: ...is too short Set the value to at least 100ms contact output type Start signal input is disabled during timing Output mode b 1 Repeat cycle 2 timer does not reset when power comes ON Timing starts whe...

Страница 21: ...is OFF A sustained control output is used Timing Timing Sustained Power Start signal input Output Basic Operation Output is instantaneous when setting is 0 Z mode ON OFF duty adjustable flicker Timin...

Страница 22: ...if the ON OFF time is too short Set the value to at least 100ms contact output type Start signal input is disabled during timing Output Mode ton flicker ON start Timing starts when the start signal g...

Страница 23: ...The names in parentheses are used for the absolute value setting Output is instantaneous when the set value is 0 Start signal input is disabled during timing F 1 Mode Cumulative Timer does not reset w...

Страница 24: ...ons without Flush Mounting Adapter Note M3 terminal screw effective length 8mm Dimensions with Flush Mounting Adapter Panel Cutouts Note The mounting panel thickness should be 1 5 mm To allow easier o...

Страница 25: ...mer Dimensions Note all units are in millimeters unless otherwise indicated Dimensions without DIN Track Mounting Adapter Note M3 terminal screw effective length 8mm Dimensions without DIN Track Mount...

Страница 26: ...r separately Waterproof Packing Flush Mounting Adapter End Plate CABC 44 Mounting Track PR 43 BK 6 0F A order separately ADP 090401 apdater changing 4 into 9 PIN Panel Protective Cover Communication P...

Страница 27: ...ion to a voltage output sensor Gate CP1 Reset 2 Reset 1 Signal CP2 External voltage External voltage When SW is pressed the transistor is ON that shows the input has response Contact Input Gate CP1 Re...

Страница 28: ...nnection to NPN open collector output sensor Gate CP1 Reset 2 Reset 1 Signal CP2 External voltage External voltage When SW is pressed the transistor is ON that shows the input has no response No conta...

Страница 29: ...d OFF using a relay with a rated capacity of 10A minimum to prevent contact deterioration due to inrush current caused by turning the power ON and OFF Be sure that the power voltage can be immediately...

Страница 30: ...it from water penetration through the space between the TC Pro and operating panel attach a waterproof packing between TC Pro and installation panel and secure the waterproof packing with the BK 62 fl...

Страница 31: ...OFF set time PV ON set time Function setting mode OFF time range ON time range Timer mode ON OFF start mode Input signal width NPN PNP input mode Key protection level Note For details on the above flo...

Страница 32: ...e range min 000000 min 0000 00 9999 59 Time range h min 0000 00 h min 00000 0 99999 9 Time range h 00000 0 h 000000 999999 Time range h 000000 h 000 000 999 999 Time range s 000 000 s Present value Sa...

Страница 33: ...0 9999 59 Time range min s 0000 00 min s 00000 0 99999 9 Time range min 00000 0 min 000000 999999 Time range min 000000 min 0000 00 9999 59 Time range h min 0000 00 h min 00000 0 99999 9 Time range h...

Страница 34: ...ing value Same as the present value of the set value above Same as left Same as left Present value Same as the present value of the set value above Same as left Same as left absolute value setting Set...

Страница 35: ...List of Models...

Отзывы: