22
Multifunction LCD Digital Timer
2-Stage Timer Operation
A Mode: Signal ON delay (Timer resets when power comes ON.)
Timing starts when the start signal turns ON.
While the start signal is ON, the timer starts when
the power turns ON or when the reset input turns
OFF.
A sustained control output is used.
Timing stops when the time is up.
Timing
Power
Start signal input
Forecast output
(Control output 1)
OUT 1
Forecast output
(Control output2)
OUT 2
Basic Operation
The names in parentheses are used for the
absolute value setting.
Output is instantaneous when the set value is 0.
Start signal input is disabled during timing.
F-1 Mode: Cumulative (Timer does not reset when power comes ON.)
Timing is enabled by start signal (timing is stopped
when the start signal is OFF or when the power is
OFF).
A sustained control output is used.
Timing continues even after the time is up.
Timing
Timing
Sustained
Start signal input
Power
Forecast output
(Control output 1)
OUT 1
Forecast output
(Control output2)
OUT 2
Basic Operation
The names in parentheses are used for the
absolute value setting.
Output is instantaneous when the set value is 0.
■