We recommend that installation be made by a licensed electrician.
Disconnect power at main panel prior to installing or servicing this
time switch or the equipment connected to it.
Connect in accordance with national and local electrical codes.
Supply Connections: Use gauge specified (AWG #8-14 ) suitable for 75
º
C
(167
º
F). Replace insulator before turning on electricity to unit.
INSTALLATION AND OPERATING INSTRUCTIONS
TO SET ON AND OFF TIMES:
Light
trippers turn ON. Dark trippers turn
OFF. Place tripper on dial edge as
shown in figure and set point of each
tripper to desired operating time.
Note if selected time is AM or PM. Hold
tripper against dial edge and firmly
tighten knurled screw.
208-277VAC/60Hz
MECHANICAL
WATER HEATER
TIME SWITCH
INSTALLATION AND OPERATING
INSTRUCTIONS TO SET DIAL TO TIME:
Turn dial counter-clockwise until correct
time is indicated by arrow on nameplate.
FOR TEMPORARY MANUAL OVERRIDE:
Press down external lever on the right to turn
timer ON. Press external lever up to turn timer
OFF.
CAUTION: Do not rotate dial for manual override.
TO REMOVE MECHANISM FROM CASE:
Press lever near case latch to release mainplate and swing the
movement out. To replace, insert mainplate projections in slots
opposite latch and swing movement in until it latches.
15146
•
24 HOUR TIME SWITCH
SWITCH:
DPST
CONTACT RATINGS:
40 AMP 250V
10,00VA WATTS 250V
TIMING MOTOR:
208-277VAC 60Hz
POWER CONSUMPTION: 3 WATTS MAX
Typical Wiring Diagram,
240 VAC Application
GE5362-41K2
15146
MANUAL VERSION 1
03/25/11
WWW.JASCOPRODUCTS.COM
O
F
F
O
N
TIM
E
ON TIME
(Light Tripper)
OFF TIME
(Dark Tripper)
Knurled Screw
Dial Calibrations
OFF GREEN
EXTERNAL
OVERRIDE
SWITCH
ON RED
GREEN=OFF
RED=ON
LOAD