32
Multifunction LCD Digital Timer
Function Setting Mode
Parameter name parameter
Setting range
Default
value
Unit
Set
value
Time range
timr
--.--s/---.-s/----s/--min:--s/---.-min/
----min/--h:--min/---.-h/----h/-.---s
--.--s
---
Timer mode
timm
up/down
up
---
Output mode
outm
a/a-1/a-2/a-3/b/b-1/d/e/f/z
a
---
Output time
otim
hold/0000.01~9999.99
hold
s
Input signal width
iflt
20ms/1ms
20ms
---
NPN/PNP
input mode
imod
npn/pnp
npn
---
Key protect level
kypt
kp-1/kp-2/kp-3/kp-4/kp-5
kp-1
---
Settings for Twin Timer Operation
Run mode
Parameter name parameter
Setting range
Default
value
Unit
Set
value
OFF set time
---
0000.00~9999.99 (Time range: -.-s)
0000.00
s
---
00000.0~99999.9 (Time range: -.-s)
00000.0
s
---
000000~999999 (Time range: --s)
000000
s
---
0000:00~9999:59 (Time range: -min-s)
0000:00
min:s
---
00000.0~99999.9 (Time range: -.-min)
00000.0
min
---
000000~999999 (Time range: --min)
000000
min
---
0000:00~9999:59 (Time range: -h-min)
0000:00
h:min
---
00000.0~99999.9 (Time range: -.-h)
00000.0
h
---
000000~999999 (Time range: --h)
000000
h
---
000.000~999.999 (Time range: -.-s)
000.000
s
Present value
---
Same as OFF time above
Same as
left
Same as
left
ON duty ratio
---
Same as OFF time above
Same as
left
Same as
left
Present value
---
Same as OFF time above
Same as
left
Same as
left
Function setting mode
Parameter name parameter
Setting range
Default
value
Unit
Set
value
OFF time range
oftr
--.--s/---.-s/----s/--min--s/---.-min/
----min/--h--min/---.-h/----h/-.---s
--.--s
---
ON time range
ontr
--.--s/---.-s/----s/--min:--s/---.-min/
----min/--h--min/---.-h/----h/-.---s
--.--s
---
Timer mode
timm
up/down
up
---
ON/OFF start
mode
totm
toff/ton
toff
---
Input signal width
iflt
20ms/1ms
20ms
---
NPN/PNP
input mode
imod
npn/pnp
npn
---
Key protection
level
kypt
kp-1/kp-2/kp-3/kp-4/kp-5
kp-1
---
■
Содержание TC-Pro480 Series
Страница 1: ...Ver 3 0...
Страница 35: ...List of Models...