background image

www.armano-messtechnik.com

Operating Instructions

PAXd – Display

B08-590

09/22

Information on This Operating Instruction

This manual is not a stand-alone document. It applies 

only in connection with our operating instruction 

B08-500 for resistance thermometers and thermo-

couples as well as operating instruction B08-505 for 

the operation in explosion-hazardous areas.

This manual contains important information on the 

safe operation of the device. Before taking the device 

into operation, this manual has to be read and under-

stood by qualified personnel. 

If you have any problems or questions, please contact 

your supplier or contact us directly at:

ARMANO Messtechnik GmbH

Location Beierfeld

Am Gewerbepark 9 • 08344 Grünhain-Beierfeld

Tel.: +49 3774 58 – 0 • Fax: +49 3774 58 – 545

[email protected]

Location Wesel

Manometerstraße 5 • 46487 Wesel-Ginderich

Tel.: +49 2803 9130 – 0 • Fax: +49 2803 1035

[email protected]

1. 

Optical Buttons 

2

2. 

Using the Optical Buttons 

2

3. Display 

2

3.1   Display Views 

2

4. 

Device and Sensor Status Indication 

4

5. 

Display Menu 

4

5.1   Display 

8

5.2   Tags 

8

5.3 Calibration 

9

5.4 Simulation 

10

5.5 Sensor 

11

5.6 HART 

11

5.7  Write Protection 

12

5.8 Language 

12

5.9  HART Version 

13

6. 

Scrolling Help Text 

14

6.1  Available Units 

16

7. Programming 

18

7.1  HART Modem 

18

7.2   HART Communicator 

18

8. 

Changing the HART Protocol Version 

19

9. 

 Connection of Transmitters  

in Multidrop Mode 

19

10.  Abbreviations Used 

20

Contents

Содержание PAXd

Страница 1: ...pplier or contact us directly at ARMANO Messtechnik GmbH Location Beierfeld Am Gewerbepark 9 08344 Gr nhain Beierfeld Tel 49 3774 58 0 Fax 49 3774 58 545 mail armano beierfeld com Location Wesel Manom...

Страница 2: ...he selected parameter unless the device is write protected 2 in monitoring view switch to the previous process variable other display view decrease the value of the selected parameter unless the devic...

Страница 3: ...ter is indicated at the top of the display the currently selected value right below The value can be changed by pressing the opti cal buttons or 2 If applicable information on per missible range and c...

Страница 4: ...r 2 Using the Optical Buttons The display menu is divided into two sections basic configuration and advanced configu ration The advanced configuration is separated into nine sections display tags cali...

Страница 5: ...other menu Warning state will be forced into this state if sensor error or overrange is present Only from Monitor menu 18 Only shown if change of protocol is possible 24 First long press of and 2 simu...

Страница 6: ...Ext Pt100 CJC Type Txt 10 Internal Ext Pt100 Ext Ni100 Fixed 2 2 0 CJC Wire Res Txt 8 100 0 0 0 2 3 Pt Ni TC 3 3 3 3 3 3 3 3 3 5 4 Ohm Res Type Txt 5 Ohm kOhm 2 3 mV Voltage Type Txt 5 uV mV V 2 3 28...

Страница 7: ...selected 8 Only shown if sensor breakage detection is activated Only shown if average sensor function is selected 7 Only shown if sensor shortage detection is activated 9 Only shown if dual sensor fu...

Страница 8: ...color Txt 73 Off White Red 3 Contrast Txt 43 0 9 2 2 2 Range Bar graph Txt 44 Loop Curr Range Sensor 2 Monitor Txt 45 Sensor 1 Sensor 2 5 CJC Sensor Average 7 Differential 6 Loop Curr Range 2 2 3 25 Y...

Страница 9: ...S1 High Txt 75 27 100 0 S1 Cal High Txt 56 200 C 850 C 2 14 Set CJC High Txt 75 27 100 0 CJC Cal Hi Txt 56 40 0 135 0 2 14 26 7501V111 UK 31 Calibration only if Write protection is disabled The devic...

Страница 10: ...A 2 20 0 S1 Simul Txt 58 200 0 850 0 2 20 0 CJC Simul Txt 60 40 0 135 0 2 20 0 Diff Simul Txt 62 200 0 850 0 2 3 3 3 3 3 3 32 7501V111 UK Simulation only if Write protection is disabled The 7501 allow...

Страница 11: ...Menu these changes will be overwritten mV PV Unit Txt 5 All units mV S1 Unit Txt 5 All units 2 2 mV S2 Unit Txt 5 All units F CJC Unit Txt 5 C F K R Yes Save Txt 16 2 2 mV Avg Unit Txt 5 All units mV...

Страница 12: ...thorized modifications to the configuration The device is delivered default with write protection disabled The password 00002008 always allows access to the write protection menu Language In this menu...

Страница 13: ...a Italiano Espa ol 2 3 Yes No 2 15 Yes Save Txt 16 HART 7 HART Rev Txt 51 3 HART 7 HART 5 2 24 Yes No 2 15 34 7501V111 UK HART Revision Changing the HART revision is done from this menu Select the des...

Страница 14: ...QV assign sensor 2 to QV assign CJC sensor to QV assign internal temperature to QV assign average measurement to QV assign differential measurement to QV 21 set the lower value at the analogue output...

Страница 15: ...or type select TC K as sensor type select TC L as sensor type select TC N as sensor type select TC R as sensor type select TC S as sensor type select TC T as sensor type select TC U as sensor type sel...

Страница 16: ...22 mbar 19 9 23 g cm2 20 11 24 Pa 174 25 hPa 21 12 26 kPa 22 13 27 torr 23 14 28 atm 24 237 29 MPa 25 17 32 l min volume flow units 131 35 m3 min 26 19 36 m3 h 27 22 38 gal s 16 39 gal min 28 24 31 l...

Страница 17: ...92 147 109 g m3 93 54 110 cSt viscosity units 94 55 111 cP 95 69 112 N m energy work units 113 Wh 96 128 114 kW h 115 MWh 97 162 116 Mcal 117 kJ 98 164 118 MJ 99 165 119 Btu Sensor menu HART Display...

Страница 18: ...ile Product Input Output C ommunication Language Option 08 30 00 PRetop 5331 Date 1994 8 10 943201594 PRelectronics Analog input Analog output Serial no Inputtype Outputtype 4 20mA Upscale Sensor erro...

Страница 19: ...HART 7 or 15 HART 5 If two devices are con figured with the same address both will be excluded The device must be configured for the multidrop mode with a fixed output signal of 4 mA The maximum cur...

Страница 20: ...V QV Variables in the HART protocol PV Primary Value 4 20 mA SV Secondary Value TV Tertiary Value QV Quaternary Value CJC Cold Junction Compensation TC Thermocouple WTH Resistance Thermometer 2022 ARM...