PAXd – Display

Single Sens

Sensor Func

Txt 3

Single Sens 

Dual Sens

3-wire

Connection

Txt 7

2-wire 

3-wire 

4-wire

Temperature

Input Type

Txt 69

Voltage 

Linear Res 

Temperature

5

S1 Wire Res

Txt 8

100.0 

0.0

0

S2 Wire Res

Txt 8

100.0

0.0

 2

 2

 2

 2

 2

Differential

Meas setup

Txt 68

Average 

Differential

 2

Pt100

Pt Type

Txt 6

Pt50

Pt100

Pt200

Pt500

Pt1000 

Custom

Pt

Sensor Type

Txt 70

Pt

Ni

TC

 2

 2

Ni100

Ni Type

Txt 71

Ni50

Ni100

Ni120

Ni1000

 2

TC K

TC Type

Txt 72

TC B

TC E

TC J

TC K

TC L

TC N

TC R

TC S

TC T

TC U

TC W3

TC W5

TC Lr

Custom

Ext Pt100

CJC Type

Txt 10

Internal

Ext Pt100

Ext Ni100

Fixed

 2

 2

0

CJC Wire Res

Txt 8

100.0

0.0

 2

3

Pt

Ni

TC

3

3

3

3

3

3

3

3

*3

*5

*4

Ohm

Res Type

Txt 5

Ohm 

kOhm

 2

3

mV

Voltage Type

Txt 5

uV

mV

V

 2

3

28 

7501V111-UK

Basic configuration

*4

Only shown if 2-wire sensor connection is 

selected.

Only shown if single sensor function is 

selected.

*3

Only shown if dual sensor function is 

selected.

*5

Not available in 
HART 5 mode

If connection is 3- or 4-wire, the max. cable 
resistance is set to 10 Ohm.
This can be overwritten in the Advanced Menu.

Ext Pt 100 / Ni 100

Internal / Fixed

Single sensor

Dual sensor

Temperature

Voltage 

Lin. R 

0

Fix CJC val

Txt 12

-40.0 

135.0 

 2

200

Max Diff

Txt 15

-7000

7000

(Sensor specific)

0

Input Low

Txt 21

0

6975

(Sensor specific)

150

Input High

Txt 22

25

7000

(Sensor specific)

 2

 2

 2

°C 

Temp Unit

Txt 5

°C

°F

°R

K

 2

0.4

PV Resp

Txt 9

1.0

60.0

0.4

S1 Resp

Txt 9

1.0

60.0

 2

 2

0.4

S2 Resp

Txt 9

1.0

60.0

 2

0.4

Avg Resp

Txt 9

1.0

60.0

0.4

Diff Resp

Txt 9

1.0

60.0

 2

 2

3.50

Out Rng Lo

Txt 23

3.50

23.00

23.00

Out Rng Hi

Txt 24

3.50

23.00

 2

 2

3.50

Out Lim Lo

Txt 25

3.50

23.00

23.00

Out Lim Hi

Txt 26

3.50

23.00

 2

 2

Yes

Save ?

Txt 16

23.00

Out Broken

Txt 28

3.50

23.00

23.00

Out Shorted

Txt 29

3.50

23.00

 2

 2

Broken

Sens Error

Txt 27

Disabled

Broken

Shorted

 

*23

Both 

*23

 2

3

3

3

3

*8

*9

*5

*6

*7

*6

*21

Yes

No

 2

*15

*29

*29

*30

*30

Yes

Disp Scaling?

Txt 82

No

Yes

%

Display Unit

Txt 78

All units

 2

 2

111.11

Decimal Pt

Txt 79

11111

1111.1

111.11

11.111

1.1111

 2

0.00

Display Low

Txt 80

-999.99

999.99

100.00

Display High

Txt 81

-999.99

999.99

 2

 2

3

*30

3

0.0

Temp Low

Txt 21

-200.0

850.0

150.0

Temp High

Txt 22

-200.0

850.0

 2

 2

*29

*29

 

7501V111-UK 

29

Not available in 
HART 7 mode

*6

Only shown if differential sensor function is 

selected.

*8

Only shown if sensor breakage detection is 

activated.

Only shown if average sensor function is 

selected.

*7

Only shown if sensor shortage detection is 

activated.

*9

Only shown if dual sensor function is 

selected.

*5

*21

Only shown if TC, fixed CJC is selected.

*23

Selection not available for Voltage Input Type 

and TC Sensor Type with internal/fixed CJC.

Not available in 
HART 5 mode

If HART revision = 5, units for S1, S2, Average and 
Difference are forced to either mV or Ohm.

Units for CJC are forced to the same units as S1. 
If S1 is not = Temperature Type, Unit is set to °C.

All device variable units can be overwritten in the 
Advanced menu.

“Monitor”

Only shown if Write-protection is disabled.

*15

*29

Only shown if Temperature input is selected.

*30

Only shown if Temperature input is NOT 

selected.

Yes

No 

No

 Only shown if dual sensor function is selected.

 Only shown if differential sensor function is selected.

 Only shown if average sensor function is selected.

 Only shown if sensor breakage detection is activated.

 Only shown if sensor shortage detection is activated.

 Only shown if write protection is disabled.

 Only shown if fixed CJC is selected.

 Selection not available for voltage input type and TC sensor type with internal / fixed CJC.

 Only shown if temperature input is selected.

 Only shown if temperature input is NOT selected.

 

 

  

Not available in 

HART 5 mode

Not available in 

HART 7 mode

Содержание PAXd

Страница 1: ...pplier or contact us directly at ARMANO Messtechnik GmbH Location Beierfeld Am Gewerbepark 9 08344 Gr nhain Beierfeld Tel 49 3774 58 0 Fax 49 3774 58 545 mail armano beierfeld com Location Wesel Manom...

Страница 2: ...he selected parameter unless the device is write protected 2 in monitoring view switch to the previous process variable other display view decrease the value of the selected parameter unless the devic...

Страница 3: ...ter is indicated at the top of the display the currently selected value right below The value can be changed by pressing the opti cal buttons or 2 If applicable information on per missible range and c...

Страница 4: ...r 2 Using the Optical Buttons The display menu is divided into two sections basic configuration and advanced configu ration The advanced configuration is separated into nine sections display tags cali...

Страница 5: ...other menu Warning state will be forced into this state if sensor error or overrange is present Only from Monitor menu 18 Only shown if change of protocol is possible 24 First long press of and 2 simu...

Страница 6: ...Ext Pt100 CJC Type Txt 10 Internal Ext Pt100 Ext Ni100 Fixed 2 2 0 CJC Wire Res Txt 8 100 0 0 0 2 3 Pt Ni TC 3 3 3 3 3 3 3 3 3 5 4 Ohm Res Type Txt 5 Ohm kOhm 2 3 mV Voltage Type Txt 5 uV mV V 2 3 28...

Страница 7: ...selected 8 Only shown if sensor breakage detection is activated Only shown if average sensor function is selected 7 Only shown if sensor shortage detection is activated 9 Only shown if dual sensor fu...

Страница 8: ...color Txt 73 Off White Red 3 Contrast Txt 43 0 9 2 2 2 Range Bar graph Txt 44 Loop Curr Range Sensor 2 Monitor Txt 45 Sensor 1 Sensor 2 5 CJC Sensor Average 7 Differential 6 Loop Curr Range 2 2 3 25 Y...

Страница 9: ...S1 High Txt 75 27 100 0 S1 Cal High Txt 56 200 C 850 C 2 14 Set CJC High Txt 75 27 100 0 CJC Cal Hi Txt 56 40 0 135 0 2 14 26 7501V111 UK 31 Calibration only if Write protection is disabled The devic...

Страница 10: ...A 2 20 0 S1 Simul Txt 58 200 0 850 0 2 20 0 CJC Simul Txt 60 40 0 135 0 2 20 0 Diff Simul Txt 62 200 0 850 0 2 3 3 3 3 3 3 32 7501V111 UK Simulation only if Write protection is disabled The 7501 allow...

Страница 11: ...Menu these changes will be overwritten mV PV Unit Txt 5 All units mV S1 Unit Txt 5 All units 2 2 mV S2 Unit Txt 5 All units F CJC Unit Txt 5 C F K R Yes Save Txt 16 2 2 mV Avg Unit Txt 5 All units mV...

Страница 12: ...thorized modifications to the configuration The device is delivered default with write protection disabled The password 00002008 always allows access to the write protection menu Language In this menu...

Страница 13: ...a Italiano Espa ol 2 3 Yes No 2 15 Yes Save Txt 16 HART 7 HART Rev Txt 51 3 HART 7 HART 5 2 24 Yes No 2 15 34 7501V111 UK HART Revision Changing the HART revision is done from this menu Select the des...

Страница 14: ...QV assign sensor 2 to QV assign CJC sensor to QV assign internal temperature to QV assign average measurement to QV assign differential measurement to QV 21 set the lower value at the analogue output...

Страница 15: ...or type select TC K as sensor type select TC L as sensor type select TC N as sensor type select TC R as sensor type select TC S as sensor type select TC T as sensor type select TC U as sensor type sel...

Страница 16: ...22 mbar 19 9 23 g cm2 20 11 24 Pa 174 25 hPa 21 12 26 kPa 22 13 27 torr 23 14 28 atm 24 237 29 MPa 25 17 32 l min volume flow units 131 35 m3 min 26 19 36 m3 h 27 22 38 gal s 16 39 gal min 28 24 31 l...

Страница 17: ...92 147 109 g m3 93 54 110 cSt viscosity units 94 55 111 cP 95 69 112 N m energy work units 113 Wh 96 128 114 kW h 115 MWh 97 162 116 Mcal 117 kJ 98 164 118 MJ 99 165 119 Btu Sensor menu HART Display...

Страница 18: ...ile Product Input Output C ommunication Language Option 08 30 00 PRetop 5331 Date 1994 8 10 943201594 PRelectronics Analog input Analog output Serial no Inputtype Outputtype 4 20mA Upscale Sensor erro...

Страница 19: ...HART 7 or 15 HART 5 If two devices are con figured with the same address both will be excluded The device must be configured for the multidrop mode with a fixed output signal of 4 mA The maximum cur...

Страница 20: ...V QV Variables in the HART protocol PV Primary Value 4 20 mA SV Secondary Value TV Tertiary Value QV Quaternary Value CJC Cold Junction Compensation TC Thermocouple WTH Resistance Thermometer 2022 ARM...

Отзывы: