www.armano-messtechnik.com • p. 7 of 20 • GB • 09/22 • B75 •
B08-590
Operating Instructions
PAXd – Display
Single Sens
Sensor Func
Txt 3
Single Sens
Dual Sens
3-wire
Connection
Txt 7
2-wire
3-wire
4-wire
Temperature
Input Type
Txt 69
Voltage
Linear Res
Temperature
5
S1 Wire Res
Txt 8
100.0
0.0
0
S2 Wire Res
Txt 8
100.0
0.0
2
2
2
2
2
Differential
Meas setup
Txt 68
Average
Differential
2
Pt100
Pt Type
Txt 6
Pt50
Pt100
Pt200
Pt500
Pt1000
Custom
Pt
Sensor Type
Txt 70
Pt
Ni
TC
2
2
Ni100
Ni Type
Txt 71
Ni50
Ni100
Ni120
Ni1000
2
TC K
TC Type
Txt 72
TC B
TC E
TC J
TC K
TC L
TC N
TC R
TC S
TC T
TC U
TC W3
TC W5
TC Lr
Custom
Ext Pt100
CJC Type
Txt 10
Internal
Ext Pt100
Ext Ni100
Fixed
2
2
0
CJC Wire Res
Txt 8
100.0
0.0
2
3
Pt
Ni
TC
3
3
3
3
3
3
3
3
*3
*5
*4
Ohm
Res Type
Txt 5
Ohm
kOhm
2
3
mV
Voltage Type
Txt 5
uV
mV
V
2
3
28
7501V111-UK
Basic configuration
*4
Only shown if 2-wire sensor connection is
selected.
Only shown if single sensor function is
selected.
*3
Only shown if dual sensor function is
selected.
*5
Not available in
HART 5 mode
If connection is 3- or 4-wire, the max. cable
resistance is set to 10 Ohm.
This can be overwritten in the Advanced Menu.
Ext Pt 100 / Ni 100
Internal / Fixed
Single sensor
Dual sensor
Temperature
Voltage
Lin. R
0
Fix CJC val
Txt 12
-40.0
135.0
2
200
Max Diff
Txt 15
-7000
7000
(Sensor specific)
0
Input Low
Txt 21
0
6975
(Sensor specific)
150
Input High
Txt 22
25
7000
(Sensor specific)
2
2
2
°C
Temp Unit
Txt 5
°C
°F
°R
K
2
0.4
PV Resp
Txt 9
1.0
60.0
0.4
S1 Resp
Txt 9
1.0
60.0
2
2
0.4
S2 Resp
Txt 9
1.0
60.0
2
0.4
Avg Resp
Txt 9
1.0
60.0
0.4
Diff Resp
Txt 9
1.0
60.0
2
2
3.50
Out Rng Lo
Txt 23
3.50
23.00
23.00
Out Rng Hi
Txt 24
3.50
23.00
2
2
3.50
Out Lim Lo
Txt 25
3.50
23.00
23.00
Out Lim Hi
Txt 26
3.50
23.00
2
2
Yes
Save ?
Txt 16
23.00
Out Broken
Txt 28
3.50
23.00
23.00
Out Shorted
Txt 29
3.50
23.00
2
2
Broken
Sens Error
Txt 27
Disabled
Broken
Shorted
*23
Both
*23
2
3
3
3
3
*8
*9
*5
*6
*7
*6
*21
Yes
No
2
*15
*29
*29
*30
*30
Yes
Disp Scaling?
Txt 82
No
Yes
%
Display Unit
Txt 78
All units
2
2
111.11
Decimal Pt
Txt 79
11111
1111.1
111.11
11.111
1.1111
2
0.00
Display Low
Txt 80
-999.99
999.99
100.00
Display High
Txt 81
-999.99
999.99
2
2
3
*30
3
0.0
Temp Low
Txt 21
-200.0
850.0
150.0
Temp High
Txt 22
-200.0
850.0
2
2
*29
*29
7501V111-UK
29
Not available in
HART 7 mode
*6
Only shown if differential sensor function is
selected.
*8
Only shown if sensor breakage detection is
activated.
Only shown if average sensor function is
selected.
*7
Only shown if sensor shortage detection is
activated.
*9
Only shown if dual sensor function is
selected.
*5
*21
Only shown if TC, fixed CJC is selected.
*23
Selection not available for Voltage Input Type
and TC Sensor Type with internal/fixed CJC.
Not available in
HART 5 mode
If HART revision = 5, units for S1, S2, Average and
Difference are forced to either mV or Ohm.
Units for CJC are forced to the same units as S1.
If S1 is not = Temperature Type, Unit is set to °C.
All device variable units can be overwritten in the
Advanced menu.
“Monitor”
Only shown if Write-protection is disabled.
*15
*29
Only shown if Temperature input is selected.
*30
Only shown if Temperature input is NOT
selected.
Yes
No
No
Only shown if dual sensor function is selected.
Only shown if differential sensor function is selected.
Only shown if average sensor function is selected.
Only shown if sensor breakage detection is activated.
Only shown if sensor shortage detection is activated.
Only shown if write protection is disabled.
Only shown if fixed CJC is selected.
Selection not available for voltage input type and TC sensor type with internal / fixed CJC.
Only shown if temperature input is selected.
Only shown if temperature input is NOT selected.
Not available in
HART 5 mode
Not available in
HART 7 mode